Use of multivariate statistical techniques to optimize the simultaneous separation of 13 phenolic compounds from extra-virgin olive oil by capillary electrophoresis
Related Experiment Video
Updated: Jun 5, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Cristiano Augusto Ballus1, Adriana Dillenburg Meinhart, Roy Edward Bruns
1Department of Food Science, Faculty of Food Engineering, University of Campinas (UNICAMP), P. O. Box 6121, 13083-862 Campinas, SP, Brazil.
Abstract:
Characterization of phenolic compounds in olive oil has not been achieved as yet, owing to the complexities of their chemical structures and analytical matrix. The aim of this work is to optimize and validate a method for simultaneous separation and quantification of 13 phenolic compounds from extra-virgin olive oil: tyrosol, hydroxytyrosol, oleuropein glycoside, ferrulic acid, p-coumaric acid, cinnamic acid, p-hydroxybenzoic acid, gallic acid, caffeic acid, luteolin, apigenin, vanillic acid and 3,4-dihydroxybenzoic acid. A statistical central composite design, response surface analysis and the simultaneous optimization method of Derringer and Suich were used to separate all the peaks. These multivariate procedures were efficient in determining the optimal separation condition, using five peak-pair resolutions and runtime as responses. The optimized method employed a fused-silica capillary of 50 μm i.d.× 60 cm effective length with extended light path, 50 mmol L(-1) boric acid electrolyte, 10.2 pH, 25°C, injection of 50 mbar for 25s with application of reverse voltage (-30 kV for 5s) before setting the running voltage (+30 kV) with detection at 210 nm and a run time of 12 min. Peak resolutions are found to be very sensitive to pH values outside the 10.15-10.25 range but acceptable electropherograms can be obtained for a wide range of boric acid concentrations within this pH interval.
More Related Videos
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
07:05Microwave-Assisted Extraction of Phenolic Compounds and Antioxidants for Cosmetic Applications Using Polyol-Based Technology
Published on: August 23, 2024
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...