A prospective randomized study of automated versus mercury blood pressure recordings in hypertensive pregnancy (PRAM
Mark A Brown1, Lynne M Roberts, Callie Mackenzie
1Department of Renal Medicine, St. George Hospital and University of NSW, Sydney, NSW, Australia. mbrown@unsw.edu.au
Background:
Mercury sphygmomanometry is being replaced with automated blood pressure (BP) recording. We tested the potential impact of this change on the outcomes of pregnant women with hypertension.
Methods:
Following routine detection of hypertension by mercury sphygmomanometry, 220 pregnant women with hypertension were randomized to have all subsequent BPs recorded with either mercury sphygmomanometry or an automated BP device (Omron HEM-705CP) for the remainder of their pregnancy. We used a prospective randomized open study with blinded end points design.
Main Outcome Measures:
The primary maternal outcome measure was the number of women having any episode of severe hypertension (BP 170/110 mmHg). The primary fetal outcome measure was small for gestational age baby.
Results:
Both groups were similar in age, weight, parity, race, use of assisted reproductive technology before this pregnancy, diabetes prevalence, smoking, mercury BP in the first trimester, use of antihypertensives at the time of study entry, and type of hypertension (essential, gestational or preeclampsia) at study entry. Severe hypertension occurred in 39% of women using mercury sphygmomanometry and 44% using the automated device (p = 0.5). Small for gestational age rates were 12 and 17%, respectively (p = 0.3). About 47% of women had preeclampsia at delivery. Birth weight and perinatal mortality were similar between groups.
Conclusions:
Using this automated BP recording device in hypertensive pregnant women is associated with similar maternal and fetal outcomes as in women whose BP is measured by sphygmomanometry, despite intra-individual BP differences between the two methods of recording BP.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Hypertension III: Clinical Manifestations and Diagnostic Studies
Errors occurring during blood pressure monitoring
Several factors...