[Dual-energy computed tomographic angiography of head and neck with dual-source computed tomography: image quality
Xuan Wang1, Hua-dan Xue, Wei Liu
1Department of Radiology, PUMC Hospital, Beijing 100730, China.
Objective:
To investigate the image quality and radiation dose of dual-energy (DE) computed tomographic angiography (CTA) of head and neck.
Methods:
We retrospectively analyzed two groups of patients (both n=30) undergoing 64-slice spiral CTA of cervical and cranial regions with different scan protocols. The DE group was obtained with 140/80 kVp, 64/272 mAs, 0.6 pitch, 80 ml of contrast medium, and caudal-cranial scan orientation. The single-energy (SE) group was obtained with 120 kVp, 220 mAs, 1.2 pitch, 60 ml of contrast medium and cranial-caudal scan orientation. The image quality and radiation dose were compared. The attenuation values and noises were measured on transverse images at 4 different vessels (the distal part of common carotid artery and adjacent vein in same axial image; the M1 segment of middle cerebral artery and sigmoid sinus or confluence of sinus in same image) and two muscles: erector spinae presenting average soft tissue enhancement and supraspinatus muscle presenting regions of great artifact.
Results:
In cranial region the arterial enhancement and venous contamination were similar (P=0.1427,P=0.1116) . In cervical region the arterial enhancement was similar (P=0.9414) . DE group had significantly greater venous contamination (P<0.0001) , while the mean attenuation value of common carotid artery was still 127 Hu higher than that of jugular vein. No matter artifact of soft tissue was obvious or not, the noise of DE group was significantly less than that of SE group (both P<0.0001) , and the soft tissue enhancement was similar (P=0.0760,P=0.0793) . The radiation dose required for bone-subtraction angiography was significantly less in DE group than in SE group (P<0.0001) .
Conclusions:
DE group has comparable image quality to SE group and less scan dose for bone-subtraction. DE-CTA has great potential in clinical application. "
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...