Beyond conventional considerations: newer devices used in blood pressure measurement and management
Raymond R Townsend1, Domenic A Sica
1Section of Clinical Pharmacology and Hypertension, Division of Nephrology, Virginia Commonwealth University Health System, Richmond, VA, USA. townsend@exchange.upenn.edu
Abstract:
Several noninvasive devices are now available to assess blood vessel structure and function and have been shown in longitudinal cohort studies to provide additional cardiovascular event prediction over that obtained by conventional brachial blood pressure (BP) measurements. Among these newer measurements are estimates of vascular stiffness (as determined by the pulse wave velocity in the aorta) and measures of pulse wave reflection. Pulse wave velocity, in particular, has been well studied in end-stage kidney (ESKD) populations where it predicts cardiovascular events and death independently of standard BP. In addition, there are minimum 3 devices, either marketed or used in clinical trials, that are useful in some clinical situations as an adjunct to drug therapy for managing high BP. This review will focus on the roles of these new technologies in evaluating and managing high BP, emphasizing the CKD/ESKD patient where possible, although data are limited in the kidney disease population when it comes to managing BP with these novel device approaches.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement