Related Experiment Video
Updated: Jun 5, 2026

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Transfer-volume effects in two-dimensional chromatography: adsorption-phenomena in second-dimension size-exclusion
Eva Reingruber1, Jeroen J Jansen, Wolfgang Buchberger
1Institute of Analytical Chemistry, Johannes Kepler University, 4040 Linz, Austria. eva.reingruber@jku.at
Abstract:
Gradient-elution LC × LC is a valuable technique for the characterization of complex biological samples as well as for synthetic polymers. Breakthrough and viscous fingering may yield misleading information on the sample characteristics or deteriorate separation. In LC × SEC another phenomenon may jeopardize the separation. If the analytes adsorb on the SEC column under the injection-plug conditions, peak splitting may occur. In LC × LC the effluent from the first column is the sample solvent for the analytes injected into the second dimension. If a gradient-elution LC × SEC setup is used (i.e. if reversed-phase gradient-elution LC is coupled to organic SEC and if normal-phase gradient-elution LC is coupled to SEC with a polar solvent), the percentage of weak solvent may be significant, especially at short analysis times. In this case adsorption in the first-dimension-effluent zone on the second-dimension SEC column can become an issue and two peaks--the first eluting in size-exclusion mode and the second undergoing adsorption--can be obtained. The work presented in this paper documents peak splitting in LC × SEC of polymers. The adsorption of the polymer on the size-exclusion column was proven in one-dimensional isocratic runs. The observed effects were modeled and visualized through simulation. Studies on the influence of the transfer volume were carried out. Keeping the transfer volume as small as possible helped to minimize peak splitting due to adsorption.
Related Concept Videos
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Chromatographic Methods: Terminology
Analyte Adsorption and Distribution