Related Experiment Video
Updated: Jun 5, 2026

Design and Construction of an Urban Runoff Research Facility
Published on: August 8, 2014
Uncertainties in stormwater runoff data collection from a small urban catchment, Southeast China
Jinliang Huang1, Zhenshun Tu, Pengfei Du
1Environmental Science Research Center, Xiamen University, Xiamen 361005, China. jlhuang@xmu.edu.cn
Abstract:
Monitoring data are often used to identify stormwater runoff characteristics and in stormwater runoff modelling without consideration of their inherent uncertainties. Integrated with discrete sample analysis and error propagation analysis, this study attempted to quantify the uncertainties of discrete chemical oxygen demand (COD), total suspended solids (TSS) concentration, stormwater flowrate, stormwater event volumes, COD event mean concentration (EMC), and COD event loads in terms of flow measurement, sample collection, storage and laboratory analysis. The results showed that the uncertainties due to sample collection, storage and laboratory analysis of COD from stormwater runoff are 13.99%, 19.48% and 12.28%. Meanwhile, flow measurement uncertainty was 12.82%, and the sample collection uncertainty of TSS from stormwater runoff was 31.63%. Based on the law of propagation of uncertainties, the uncertainties regarding event flow volume, COD EMC and COD event loads were quantified as 7.03%, 10.26% and 18.47%.