Serum metal ion concentration: comparison between small and large head metal-on-metal total hip arthroplasty

Rhett K Hallows1, Christopher E Pelt, Jill A Erickson

  • 1Intermountain Orthopaedic Specialty Group, LDS Hospital, Salt Lake City, Utah, USA. *Intermountain Orthopaedic Specialty Group, LDS Hospital, Salt Lake City, Utah, USA.

Insights

Serum chromium and cobalt levels were compared in hip replacement patients. Metal-on-metal implants showed higher ion levels than metal-on-polyethylene, indicating potential concerns for these artificial hip joints.

Area of Science:

  • Orthopedic Surgery
  • Biomaterials Science
  • Toxicology

Background:

  • Metal-on-metal hip articulations have raised concerns regarding ion release.
  • Understanding serum metal ion concentrations is crucial for evaluating implant safety and longevity.
  • Previous studies have shown variable results regarding chromium and cobalt levels in patients with metal-on-metal hip prostheses.

Purpose of the Study:

  • To compare serum metal ion concentrations (chromium and cobalt) in patients with metal-on-metal (MOM) hip articulations versus a metal-on-polyethylene (MOP) control group.
  • To investigate the relationship between head size in MOM implants and serum ion levels.
  • To assess the correlation between serum ion levels and patient-reported outcomes and radiographic findings.

Main Methods:

  • A comparative study involving 46 patients with well-functioning hips.
  • Three groups were analyzed: two with MOM articulations (small and large head sizes) and one control MOP group.
  • Serum chromium and cobalt levels were measured. Harris Hip Score, UCLA activity score, and radiographs were also performed.

Main Results:

  • Serum chromium concentrations were significantly lower in the large head MOM group compared to the small head MOM group (P = .013).
  • No significant difference in serum cobalt concentrations was found between the two MOM groups (P = .087).
  • Both MOM groups exhibited significantly higher serum chromium and cobalt levels compared to the MOP control group (P < .001 for all comparisons).

Conclusions:

  • Metal-on-metal hip articulations result in elevated serum chromium and cobalt levels compared to metal-on-polyethylene implants.
  • Larger head MOM implants may lead to lower serum chromium levels than smaller head MOM implants, though cobalt levels did not differ significantly.
  • The findings underscore the systemic exposure to metal ions associated with MOM hip prostheses, necessitating careful patient monitoring.