Related Experiment Video
Updated: Jun 5, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
The potential for delivery of particulate matter through positive airway pressure devices (CPAP/BPAP)
David Kristo1, Timothy Corcoran, Nina O'Connell
1Division of Pulmonary, Allergy, and Critical Care Medicine, University of Pittsburgh, Pittsburgh, PA 15213, USA. kristoda@upmc.edu
Background:
Airborne particulate matter may induce health risk with inhalation. Special concerns exist for deployed military personnel with inhaled particulate matter in desert environments. Continuous positive airway pressure (CPAP) used in obstructive sleep apnea may facilitate inhalation of particulate matter. We evaluated the ability of commercial CPAP filter systems to eliminate inhalation of particulate matter.
Methods:
An ultrasonic medical nebulizer (DeVilbliss Ultraneb, DeVilbliss, Somerset, PA) atomized liquid producing "respirable" aerosol. Technetium-99m diethylene triamine pentaacetic acid dissolved in water was also aerosolized to quantify aerosol inhalation. A high efficiency particulate air (HEPA) filter placed at the patient-hose connection port in the bilevel positive airway pressure (BPAP) device captured the aerosol inbound to the patient. The HEPA filter provided a means to quantify aerosol dose delivered to a simulated patient. Commercial foam and ultrafine filters were assessed with aerosol to determine the simulated patient exposure.
Results:
Foam and ultrafine filters used together allowed 1.5% or less of aerosol volume to pass through the BPAP system. Foam filters alone allowed an average of 18.9% of aerosol delivered to pass through the BPAP system.
Conclusions:
Foam and ultrafine filters used together in BPAP systems provide excellent aerosol filtration in this laboratory simulation of BPAP use.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Inhaled Medications
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...