Related Experiment Video
Updated: Jun 5, 2026

An Open-Source Normothermic Perfusion System Designed for Research Scientists
Published on: July 18, 2025
Evaluation of a new online hemodiafiltration mode with automated pressure control of convection
U Teatini1, D Steckiph, G Romei Longhena
1Nephrology and Dialysis Unit, Ospedale 'Caduti Bollatesi', Bollate, Italy. nefrologiab@aogarbagnate.lombardia.it
Background:
Postdilution hemodiafiltration (HDF) still remains the gold standard for solute removal, but with high hemoglobin levels transmembrane pressure (TMP) may reach high levels, reducing filter performance. We compared three online postdilution HDF treatments without TMP alarms for convective volume and plasma changes following treatment.
Methods:
Twelve patients were enrolled in a trial with three online postdilution HDF treatments. In the volume-controlled mode (VOLc), we set the exchanged volume to obtain a filtration fraction close to 25% without TMP alarms. In the pressure-controlled mode (TMPc), we set the TMP at 100 mm Hg. In the ULTRAc mode (TMP scan combined with TMPc), the dialysis machine automatically selects the TMP with a scan. All treatments were performed with an AK200 ULTRA-S system.
Results:
Even with hemoglobin levels >12 g/dl, we found a 57% rise in ultrafiltration rate in TMPc versus VOLc and a 92% rise in ULTRAc versus VOLc. Phosphates and myoglobin levels were significantly affected by treatment type.
Conclusions:
ULTRAc may be a useful tool to achieve an excellent purification performance without the constraints associated with the risk of hemoconcentration.