Related Experiment Video
Updated: Jun 5, 2026

Development of a More Sensitive and Specific Chromogenic Agar Medium for the Detection of Vibrio parahaemolyticus and Other Vibrio Species
Published on: November 8, 2016
The development of loop-mediated isothermal amplification combined with lateral flow dipstick for detection of Vibrio
P Prompamorn1, P Sithigorngul, S Rukpratanporn
1Department of Biology, Faculty of Science, Srinakharinwirot University, Bangkok, Thailand.
Aims:
The current study was aimed to develop a loop-mediated isothermal amplification (LAMP) combined with amplicon detection by chromatographic lateral flow dipstick (LFD) assay for rapid and specific detection of Vibrio parahaemolyticus.
Methods And Results:
Biotinylated LAMP amplicons were produced by a set of four designed primers that recognized specifically the V. parahaemolyticus thermolabile haemolysin (tlh) gene followed by hybridization with an FITC-labelled probe and LFD detection. The optimized time and temperature conditions for the LAMP assay were 90 min at 65 °C. The LAMP-LFD method accurately identified 28 isolates of V. parahaemolyticus but did not detect 24 non-parahaemolyticus Vibrio isolates and 35 non-Vibrio bacterial isolates. The sensitivity of LAMP-LFD for V. parahaemolyticus detection in pure cultures was 120 CFU ml⁻¹. In the case of spiked shrimp samples without enrichment, the detection limit for V. parahaemolyticus was 1·8 x 10³ CFU g⁻¹ or equivalent to 3 CFU per reaction while that of conventional PCR was 30 CFU per reaction.
Conclusions:
The established LAMP-LFD assay targeting tlh gene was specific, rapid and sensitive for identification of V. parahaemolyticus.
Significance And Impact Of The Study:
The developed LAMP-LFD assay provided a valuable tool for detection of V. parahaemolyticus and can be used effectively for identification of V. parahaemolyticus in contaminated food sample.
More Related Videos
07:47Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Assay for the Specific and Rapid Detection of Tilapia Lake Virus
Published on: May 18, 2020
07:27The Development of Lyophilized Loop-mediated Isothermal Amplification Reagents for the Detection of Coxiella burnetii
Published on: April 18, 2016