Related Experiment Video
Updated: Jun 5, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Is there a common SUV threshold in oncological FDG PET/CT, at least for some common indications? A retrospective
Nghi C Nguyen1, Aarti Kaushik, Michael K Wolverson
1Saint Louis University School of Medicine, Department of Radiology, Division of Nuclear Medicine, MO 63110, USA. nguyenn@slu.edu
Purpose:
We retrospectively compared the maximum standard uptake value (SUVmax) of FDG PET in four different sites to evaluate whether a common diagnostic SUVmax threshold may exist in these tumor locations. We further postulate that the SUVmax thresholds are higher in thoracic lesions than in extrathoracic lesions.
Material And Methods:
N = 143 patients in four subgroups underwent a FDG PET/CT: a) 42 patients for solitary pulmonary nodules (SPNs) characterization with b) respective mediastinal lymph nodes (LNs), c) 65 patients for LN staging of head and neck cancer, and d) 36 cancer patients diagnosed with adrenal lesions. Receiver operating characteristics of SUVmax values were evaluated.
Results:
The SUVmax were statistically significantly greater in malignant than in benign lesions. For SPNs and mediastinal LNs, a SUVmax > 3.6 each resulted in a sensitivity of 81% and 87%, and a specificity of 94% and 89%. For cervical LNs and adrenal glands, a SUVmax > 2.2 each showed a sensitivity of 98% and 100%, and a specificity of 83% and 93%.
Conclusion:
A common SUVmax threshold did not exist in the four studied subgroups. The variable FDG uptake in SPNs and mediastinal LNs are associated with the high prevalence of inflammation/infection within the chest. Similar SUVmax thresholds however may exist for extrathoracic regions where the prevalence of inflammation/infection is low.
More Related Videos
10:04Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)
Published on: May 2, 2012
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...