Impact of blood pressure cuff inflation rates on flow-mediated dilatation and contralateral arm response
Related Experiment Video
Updated: Jun 5, 2026

Ultrasound Assessment of Flow-Mediated Dilation of the Brachial and Superficial Femoral Arteries in Rats
Published on: November 3, 2016
H-F Lin1, M S Dhindsa, T Tarumi
1Department of Kinesiology and Health Education, University of Texas, Austin, TX 78712, USA.
Abstract:
Flow-mediated dilatation (FMD) is widely used as an index of nitric oxide-mediated vasodilator function, yet its methodology has not been well established. Previous research indicates that a rapid inflation of a blood pressure cuff evokes systemic vasoconstriction, as it was observed even on non-occluded contralateral arm. This would potentially contribute to the variability of FMD readings and complicate the emerging evidence that non-occluded contralateral arm fingertip temperature responses during the FMD procedure may be an indicator of the presence of coronary artery disease. To test the hypotheses that rapid inflation of a blood pressure cuff could reduce FMD values and influence contralateral vasodilatory states, 33 apparently healthy adults (18 males and 15 females, 29±6 years) were studied in two randomized FMD trials. The blood flow-occluding cuff was inflated rapidly (<1 s) in one trial or slowly over 10 s in the other trial. Arterial diameter, fingertip temperature and infrared thermography were obtained throughout each session. FMD values were not different between the rapid and slow cuff inflation trials (5.9±0.6 vs 5.9±0.4%). There were no differences in reactive hyperaemia (6.4±1.6 vs 6.2±1.7 AU), shear stress (80±20 vs 77±17 dyn cm(-2)) and fingertip temperature rebound (TR; 1.8±1.2 vs 1.9±1.0 °C) between the rapid and slow inflation. Changes in finger temperature on the contralateral (non-occluded) arm were positively associated with those on the occluded arm (r=0.26 to 0.61, P<0.05). We concluded that rates of inflating a blood pressure cuff do not affect FMD and TR response, and that neurovascular-induced vasodilatation of the contralateral arm was not observed regardless of cuff inflation rates.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...