Anatomic attachment of the ACL. Comparison between radiological and CT analysis
Jean-Yves Jenny1, Eugène Ciobanu, Philippe Clavert
1Centre de Chirurgie Orthopédique et de la Main, Hôpitaux Universitaires de Strasbourg, 10 Avenue Baumann, 67400, Illkirch, France. jean-yves.jenny@chru-strasbourg.fr
Purpose:
The following hypothesis was tested: the location of the tibial and femoral anterior cruciate ligament (ACL) attachments will differ according to the measurement technique (plain radiographs or CT-scan) in relation to the anatomic frame of reference.
Methods:
10 gross specimens were studied. The location of metallic reference pins implanted around the tibial and femoral ACL attachments was recorded with reference to the bone contours with a caliper on the anatomic preparation, with standard plain AP and lateral radiographs and with a CT-scan. Results were compared with appropriate statistical tests at a 0.05 level of significance.
Results:
The mean ratio between the antero-posterior tibia measurement and the center of the ACL tibial attachment varied from 50 to 52%. The mean ratio between the medio-lateral tibia measurement and the center of the ACL tibial attachment varied from 49 to 51%. The mean ratio between the antero-posterior femur measurement and the center of the ACL femoral attachment varied from 74 to 80%. The results were significantly different between the three techniques (respectively P = 0.003, P = 0.02 and P = 0.045).
Discussion:
The paired differences were small (3% at the tibia, 6% at the femur). There was a strong correlation and a good agreement between the three techniques. It is likely that the small differences on the tibia have few, if any, clinical relevance.
Conclusion:
Both radiographic and CT-scan measurement techniques used during the present study have the potential to be used as quality control after ACL replacement.
Level Of Evidence:
Diagnostic study-investigating a diagnostic test. Development of diagnostic criteria in a consecutive series of patients and a universally applied "gold" standard, Level II.