S C Partridge1, H Rahbar, R Murthy
1Department of Radiology, University of Washington, Seattle, Washington 98109-1023, USA. scp3@u.washington.edu
Abstract:
This study investigated the relationship between apparent diffusion coefficient (ADC) measures and dynamic contrast-enhanced magnetic resonance imaging (MRI) kinetics in breast lesions and evaluated the relative diagnostic value of each quantitative parameter. Seventy-seven women with 100 breast lesions (27 malignant and 73 benign) underwent both dynamic contrast-enhanced MRI and diffusion weighted MRI. Dynamic contrast-enhanced MRI kinetic parameters included peak initial enhancement, predominant delayed kinetic curve type (persistent, plateau, or washout), and worst delayed kinetic curve type (washout > plateau > persistent). Associations between ADC and dynamic contrast-enhanced MRI kinetic parameters and predictions of malignancy were evaluated. Results showed that ADC was significantly associated with predominant curve type (ADC was higher for lesions exhibiting predominantly persistent enhancement compared with those exhibiting predominantly washout or plateau, P = 0.006), but was not significantly associated with peak initial enhancement or worst curve type (P > 0.05). Univariate analysis showed significant differences between benign and malignant lesions in both ADC (P < 0.001) and worst curve (P = 0.003). In multivariate analysis, worst curve type and ADC were significant independent predictors of benign versus malignant outcome and in combination produced the highest area under the receiver operating characteristic curve (0.85 and 0.78 with 5-fold cross validation).
More Related Videos
06:24Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
10:25A Dorsal Skinfold Window Chamber Tumor Mouse Model for Combined Intravital Microscopy and Magnetic Resonance Imaging in Translational Cancer Research
Published on: April 12, 2024
Related Concept Videos
Magnetic Resonance Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...