Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next sampling...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Does Manual Drilling Improve the Healing of Bone-Hamstring Tendon Grafts in Anterior Cruciate Ligament Reconstruction? A Histological and Biomechanical Study in a Rabbit Model.

Orthopaedic journal of sports medicine·2020
Same author

The Challenge of Managing the "Third-Space" in Total Knee Arthroplasty: Review of Current Concepts.

Joints·2018
Same author

Return to sport activity after anterior cruciate ligament reconstruction in skeletally immature athletes with manual drilling original all inside reconstruction at 8 years follow-up.

Acta orthopaedica et traumatologica turcica·2016
Same author

Changes in Plasma β-NGF and Its Receptors Expression on Peripheral Blood Monocytes During Alzheimer's Disease Progression.

Journal of Alzheimer's disease : JAD·2016
Same author

Congenital Pseudoarthrosis of Medial Malleolus in A Young Soccer Player - Diagnosis in Clinical setting of Ankle Sprain.

Journal of orthopaedic case reports·2016
Same author

Electromechanical delay of the knee flexor muscles after anterior cruciate ligament reconstruction using semitendinosus tendon.

Sports biomechanics·2015

Related Experiment Video

Updated: Jun 5, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
14:14

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement

Published on: December 11, 2017

ACL reconstruction with "the original all-inside technique".

Giuliano Cerulli1, Giovanni Zamarra, Fabio Vercillo

  • 1Department of Orthopedics and Traumatology, School of Medicine University of Perugia and Let People Move, Via GB Pontani 9, 06128, Perugia, Italy. letpeoplemove@tin.it

Knee Surgery, Sports Traumatology, Arthroscopy : Official Journal of the ESSKA
|January 25, 2011
PubMed
Summary

The original all-inside anterior cruciate ligament (ACL) reconstruction technique uses double half tunnels for graft fixation. This method aims to enhance the graft-bone contact area quality.

More Related Videos

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
06:26

Novel and Innovative Hybrid Technique for Type A Aortic Dissection

Published on: March 28, 2025

Related Experiment Videos

Last Updated: Jun 5, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
14:14

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement

Published on: December 11, 2017

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
06:26

Novel and Innovative Hybrid Technique for Type A Aortic Dissection

Published on: March 28, 2025

Area of Science:

  • Orthopedic surgery
  • Sports medicine
  • Biomedical engineering

Background:

  • Knee arthroscopy has advanced significantly, making anterior cruciate ligament (ACL) reconstruction a common orthopedic procedure.
  • Various surgical techniques exist for ACL reconstruction, each with unique advantages and challenges.

Purpose of the Study:

  • To describe the "original all-inside technique" for anterior cruciate ligament (ACL) reconstruction.
  • To evaluate the potential of this technique in improving graft-bone contact area quality.

Main Methods:

  • Utilizes manually drilled double half tunnels within the bone tunnels.
  • Employs a single tendon graft, which is triplicated or quadruplicated for fixation.

Main Results:

  • The technique allows for the use of a single tendon graft, prepared in a triplicated or quadruplicated fashion.
  • Aims to optimize the interface between the bone and the graft material.

Conclusions:

  • The "original all-inside technique" offers a method for ACL reconstruction using specific tunnel preparation and graft configuration.
  • This approach may lead to improved graft incorporation and healing by enhancing the contact area between the graft and the bone bed.