Related Experiment Video
Updated: Jun 5, 2026

P50 Sensory Gating in Infants
Published on: December 26, 2013
Aeration properties of a new sleeping surface for infants
Ephraim Bar-Yishay1, Mark Gaides, Avner Goren
1Pulmonary Function Laboratory, Pediatric Pulmonary Institute, Schneider Children's Medical Center of Israel, Petach Tikva, Israel. ephraimby@gmail.com
Background:
Prone sleeping position, use of soft mattresses and head covering by bedclothes are known risk factors for sudden infant death syndrome (SIDS). Rebreathing carbon dioxide (CO(2) ) may be a possible mechanism or a confounding factor of SIDS.
Objective:
To compare the aeration properties of a new concept of infant sleeping surface (Net) to three commercial mattresses advertised to improve aeration and to two standard infant mattresses.
Design:
Two experiments were performed: (I) A container (head box), filled with 7% CO(2) mixture, was opened to the mattress to allow gas mixture to passively diffuse outside and equilibrate with the surrounding room air. (II) Simulation of normal breathing of an infant, using a unidirectional reciprocal syringe, to determine CO(2) accumulation within the head box.
Methods:
CO(2) concentrations in the head box were continuously measured until CO(2) levels fell below 1% or for 5 min (experiment I), or until CO(2) accumulation levels plateaued or for 6 min (experiment II).
Results:
The Net had a significantly faster rate of CO(2) elimination (88.5 ± 4.6 and 91.9 ± 0.9 sec, Net alone and when covered with a sheet, respectively) compared to 238.3 ± 14.2 sec to 387.8 ± 7.9 sec for the other mattresses (P < 0.001). Only the Net was able to prevent CO(2) accumulation with maximal CO(2) levels (0.56 ± 0.03% and 1.16 ± 0.05%; Net alone and when covered with a sheet, respectively) significantly lower than the range of 4.6-6.3% for the other mattresses (P < 0.001).
Conclusions:
The new sleeping surface exhibited significantly better aeration properties in dispersing CO(2) and in preventing its accumulation.
More Related Videos
Related Concept Videos
Breathing
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the aggregate...
Air-entraining Agents
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Effects of Air-entrainment in Concrete