Related Experiment Video
Updated: Jun 5, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Pressure support improves oxygenation and lung protection compared to pressure-controlled ventilation and is further
Peter M Spieth1, Alysson R Carvalho, Andreas Güldner
1Department of Anesthesiology and Intensive Care Therapy, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Dresden, Germany.
Objectives:
To explore whether 1) conventional pressure support ventilation improves lung function and attenuates the pulmonary inflammatory response compared to pressure-controlled ventilation and 2) random variation of pressure support levels (noisy pressure support ventilation) adds further beneficial effects to pressure support ventilation.
Design:
Three-arm, randomized, experimental study.
Setting:
University hospital research facility.
Subjects:
Twenty-four juvenile pigs.
Interventions:
Acute lung injury was induced by surfactant depletion. Animals were randomly assigned to 6 hrs of mechanical ventilation (n = 8 per group) with either 1) pressure-controlled ventilation, 2) pressure support ventilation, or 3) noisy pressure support ventilation. During noisy pressure support ventilation, the pressure support varied randomly, with values following a normal distribution. In all groups, the driving pressures were set to achieve a mean tidal volume of 6 mL/kg. At the end of experiments, animals were killed and lungs extracted for histologic and biochemical analysis.
Measurements And Main Results:
Respiratory, gas-exchange, and hemodynamics variables were assessed hourly. The diffuse alveolar damage and the inflammatory response of lungs were quantified. Pressure support ventilation and noisy pressure support ventilation improved gas exchange and were associated with reduced histologic damage and interleukin-6 concentrations in lung tissue compared to pressure-controlled ventilation. Noisy pressure support ventilation further improved gas exchange and decreased the inspiratory effort while reducing alveolar edema and inflammatory infiltration compared to pressure support ventilation.
Conclusions:
In this model of acute lung injury, pressure support ventilation and noisy pressure support ventilation attenuated pulmonary inflammatory response and improved gas exchange as compared to pressure-controlled ventilation. Noisy pressure support ventilation further improved gas exchange, reduced the inspiratory effort, and attenuated alveolar edema and inflammatory infiltration as compared to conventional pressure support ventilation.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...