Related Experiment Video
Updated: Jun 5, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Evaluation of mediastinal lymph nodes using F-FDG PET-CT scan and its histopathologic correlation
Arvind Kumar1, Roman Dutta, Umashankkar Kannan
1Department of Surgical Disciplines, New Delhi, India.
Aims And Objectives:
To determine the efficacy of integrated (18)F-fluorodeoxy glucose positron emission tomography-computed tomography ((18)F-FDG PET-CT) in the evaluation and characterization of mediastinal lymph nodes into benign and malignant pathology.
Methods:
Thirty-five patients with mediastinal lymphadenopathies without primary neoplastic or infective lung pathologies were included in the study. The lymph nodes were detected on contrast-enhanced CT scan of the chest. All patients underwent (18)F-FDG PET-CT scan for evaluation of mediastinal lymph nodes. Results of PET-CT were compared with histopathology of the lymph nodes and sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated.
Statistical Analysis:
The data were collected prospectively and analyzed using (SPSS Inc., Chicago, IL) 11.5 software.
Results:
Histopathology results in 35 patients revealed tuberculosis in 12, sarcoidosis in 8, and lymphoma in 15. Maximum standardized uptake value (SUVmax) of the benign lymph nodes ranged from 2.3 to 11.8 with a mean±standard deviation (SD) of 5.02±3.26. SUVmax of the malignant lymph nodes ranged from 2.4 to 34 with a mean±SD of 10.8±8.12. There was a statistically significant difference between benign and malignant pathology (P<0.0059). (18)F-FDG PET-CT has sensitivity of 93% and specificity of 40% with SUVmax 2.5 as the cutoff. We found the optimal SUVmax cutoff to be 6.2 as determined by the receiver-operator characteristic curve. With 6.2 as cutoff, the sensitivity, specificity, and accuracy were 87%, 70%, and 77%, respectively.
Conclusion:
In countries where tuberculosis and other granulomatous diseases are endemic, SUVmax cutoff value of 2.5 has low specificity. Increasing the cutoff value can improve the specificity, while maintaining an acceptable sensitivity.
More Related Videos
10:04Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)
Published on: May 2, 2012
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET