Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary
Tsuyoshi Isogai1, Masahiro Jinzaki, Yutaka Tanami
1Department of Diagnostic Radiology, Keio University School of Medicine, Tokyo, Japan.
Insights
Optimal coronary CT attenuation requires at least 0.7 ml/kg of contrast material with 350 mg/ml iodine concentration for 64-detector CT angiography. This protocol ensures higher attenuation values for better diagnostic accuracy.
Area of Science:
- Radiology
- Medical Imaging
- Cardiovascular Imaging
Background:
- Coronary CT angiography (CCTA) is crucial for diagnosing coronary artery disease.
- Optimal contrast material attenuation is essential for accurate CCTA interpretation.
- Body weight-tailored contrast injection protocols aim to standardize image quality.
Purpose of the Study:
- To evaluate a body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) coronary angiography.
- To determine the optimal contrast material volume and iodine concentration for achieving superior coronary CT attenuation.
Main Methods:
- Sixty patients undergoing CCTA were divided into three groups receiving different contrast protocols (A, B, C) varying in volume (0.6-0.7 ml/kg) and iodine concentration (300-350 mg/ml).
- Contrast injection duration was standardized at 10 seconds for all participants.
- Intracoronary attenuation values were analyzed on a per-vessel and per-patient basis, comparing proportions exceeding 325 HU.
Main Results:
- Protocol C (0.7 ml/kg, 350 mg/ml iodine) significantly increased the likelihood of exceeding 325 HU compared to protocols A and B.
- On per-vessel analysis, protocol C achieved >325 HU in 95% (reader 1) and 90% (reader 2) of cases.
- Per-patient analysis also showed significantly higher rates of >325 HU with protocol C.
Conclusions:
- A minimum of 0.7 ml/kg contrast material with 350 mg/ml iodine concentration is necessary for optimal coronary CT attenuation (>325 HU) using 64-detector CT.
- This finding is critical for enhancing diagnostic accuracy in CCTA.
- The study supports the use of higher iodine concentrations and specific volumes for improved CCTA quality.
Purpose:
The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation.
Materials And Methods:
A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg(-1) with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg(-1) with 350 mg I/ml; protocol C, total of 0.7 ml kg(-1) with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 HU was compared on a pervessel and per-patient basis.
Results:
The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P < 0.05). The attenuation value also significantly exceeded 325 HU with protocol C (95% and 90%, respectively) more often than with protocol A or B on the per-patient analysis (P < 0.05).
Conclusion:
A total of at least 0.7 ml kg(-1) contrast material with 350 mg/ml iodine concentration is required to achieve optimal coronary CT attenuation (>325 HU) with 64-detector CT when using an injection duration of 10 s.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System IV: CMRI
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...