Related Experiment Video
Updated: Jun 5, 2026

Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Zirconia nanoparticles-coated column for the capillary electrochromatographic separation of iron-binding- and
Chia-Hsin Lee1, Bao-Yu Huang, Yu-Cheng Chen
1Department of Chemistry, National Taiwan University, 1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan.
Abstract:
A ZrO(2) nanoparticles (ZrO(2)NPs)-coated column was prepared through a sol-gel process using zirconium(iv) oxychloride, which reacted with silanol groups of the fused-silica capillary. The condensation reaction was carried out at 350 °C for 8 h. Electroosmotic flow (EOF) measurements and scanning electron microscopy (SEM) images were used to characterize the ZrO(2)NPs fabricated on the inner wall of the capillary. Below the pI value (pH 5-6), cathodic EOF elucidated that the phosphate buffer adsorbs tightly on the zirconia surface, resulting in a negatively charged surface. In this work, iron-binding proteins, phosphorylated proteins and glycoproteins were selected as the model compounds. The effects of pH, concentration, buffer type and the organic modifier were studied to optimize the separation efficiency. Iron-binding proteins exhibited a retention time for myoglobin (Mb) < hemoglobin (Hb), which corresponded to the binding constants for ZrO(2)NPs. The α- and β-subunit of Hb could be separated in borate buffer (20 mM, pH 9.0) with MeOH (20%, v/v). Greater affinity of α-casein and bovine serum albumin (BSA) for the stationary phase as the pH decreased was found by comparison with that of conalbumin (ConA) and transferrin (Tf). Interestingly, 14 peaks for glycoisoforms of ovalbumin (OVA) were observed using borate buffer (40 mM, pH 9.0). The established method was also applied to the determination of analytes in the egg whites of chicken and duck eggs.
More Related Videos
Related Concept Videos
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Capillary Electrophoresis: Instrumentation
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Principles Of Column Chromatography

