Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Instrumentation Amplifier01:25

Instrumentation Amplifier

An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
MOS Capacitor01:25

MOS Capacitor

A Metal-Oxide-Semiconductor (MOS) capacitor is a fundamental structure used extensively in semiconductor device technology, particularly in the fabrication of integrated circuits and MOSFETs (metal-oxide-semiconductor field-effect transistors). The MOS capacitor consists of three layers: a metal gate, a dielectric oxide, and a semiconductor substrate.
The metal gate is typically made from highly conductive materials such as aluminum or polysilicon. Beneath the metal gate lies a thin layer of...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Ammeter01:11

Ammeter

An ammeter is a current measuring instrument. In the circuit, it is represented by the symbol A. The ammeter is placed in series with the device or component to measure the current. A series connection is used because objects in series have the same current passing through them. If a circuit has multiple resistors and the current needs to be measured in each resistor, the number of ammeters required depends on whether the circuit is in series or parallel.
When an ammeter is used to measure the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A novel G13-RAPGEF2-RAP1 signaling pathway critical for platelet adhesion and aggregation.

Blood·2026
Same author

Evaluation of 3 commercial assays for the measurement of tissue factor activity in human plasma.

Research and practice in thrombosis and haemostasis·2026
Same author

Tissue factor detection in mouse tissues by western blotting using commercial antibodies.

Research and practice in thrombosis and haemostasis·2026
Same author

Comparison of changes in blood cells and hemostatic biomarkers in mouse xenograft models of acute myeloid leukemia and acute promyelocytic leukemia.

Research and practice in thrombosis and haemostasis·2026
Same author

Potential Mechanisms Underlying Bleeding During Infection With Hemorrhagic Fever Viruses.

Arteriosclerosis, thrombosis, and vascular biology·2025
Same author

New light on the activators of factor XI in venous thromboembolism.

Lancet (London, England)·2025
Same journal

Fibrocytes drive JAK2V617F-mutated myelofibrosis: pitavastatin reverses marrow fibrosis and anemia.

Blood·2026
Same journal

Identifying steroid-refractory aGVHD before it happens.

Blood·2026
Same journal

ELISA-negative HIT: antibody recognition and relevance.

Blood·2026
Same journal

EBV and immunodeficiency: the odd couple drawn to the brain.

Blood·2026
Same journal

A bone to pick with ferric carboxymaltose.

Blood·2026
Same journal

A step toward streamlining HIT diagnosis.

Blood·2026
See all related articles

Related Experiment Video

Updated: Jun 4, 2026

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
11:18

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)

Published on: July 11, 2017

MPs or ICs?

Julie C Williams1, Nigel Mackman

  • 1University of North Carolina at Chapel Hill.

Blood
|January 29, 2011
PubMed
Summary
This summary is machine-generated.

Cell-derived microparticles (MPs) and immune complexes (ICs) share similar physical characteristics in arthritis patients. This discovery offers new insights into the biophysics of these components in joint inflammation.

More Related Videos

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh
10:42

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh

Published on: May 3, 2019

Real-time Iontophoresis with Tetramethylammonium to Quantify Volume Fraction and Tortuosity of Brain Extracellular Space
10:45

Real-time Iontophoresis with Tetramethylammonium to Quantify Volume Fraction and Tortuosity of Brain Extracellular Space

Published on: July 24, 2017

Related Experiment Videos

Last Updated: Jun 4, 2026

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
11:18

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)

Published on: July 11, 2017

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh
10:42

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh

Published on: May 3, 2019

Real-time Iontophoresis with Tetramethylammonium to Quantify Volume Fraction and Tortuosity of Brain Extracellular Space
10:45

Real-time Iontophoresis with Tetramethylammonium to Quantify Volume Fraction and Tortuosity of Brain Extracellular Space

Published on: July 24, 2017

Area of Science:

  • Rheumatology
  • Biophysics
  • Immunology

Background:

  • Cell-derived microparticles (MPs) are increasingly recognized as important players in inflammatory diseases.
  • The biophysical properties of MPs and their relationship with immune complexes (ICs) in arthritis remain incompletely understood.

Discussion:

  • This study employed multiple biophysical methods to analyze MPs from arthritis patients.
  • The findings reveal significant overlap in the biophysical properties of MPs and ICs.

Key Insights:

  • MPs and ICs exhibit similar characteristics, suggesting potential shared roles in arthritis pathogenesis.
  • These overlapping properties may influence their interactions within the synovial fluid and plasma.

Outlook:

  • Further research can explore the functional implications of these shared biophysical properties.
  • This understanding could lead to novel diagnostic or therapeutic strategies targeting MPs and ICs in arthritis.