Related Experiment Video
Updated: Jun 4, 2026

Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
Transradial percutaneous coronary interventions: technique, materials & procedure in the light of anatomical and
Johannes B Dahm1, Frank van Buuren
1Department of Cardiology-Angiology, Heart-& Vascular Center Neu-Bethlehem, Göttingen, Germany. dahm@herz-gefaesszentrum.org
Abstract:
Transradial access is associated with enhanced patients' comfort, significant lower complication rates in diagnostic coronary angiography and better immediate and long-term outcomes after transradial percutaneous coronary interventions. Access failure has been reported to occur in less than 3-7% of cases due to anatomical circumstances (e.g., anomalous radial branching patterns, tortuosity e.g. radial loops, and small radial artery diameters). Radial coronary angiography and angioplasty entail a secondary learning curve of at least 150 cases in order to become familiar and comfortable with this technique. In contrast to previous established techniques (e.g. Sones-arteriotomy), the patient should be positioned in a comfortable supine position with his right arm next to his hip and the interventionist next to the right side of the patient. 19 gauge needles and 0.018 inch wires enhance the chance of successful cannulation the radial artery. A spasmolytic cocktail (3 mg Dinitrate, 3 mg verapamil, at least 3.000 U Heparine) should always be given intraarterially. Longer sheaths (> 13 cm) are not necessary. Essential for easy passage of the vertebralian artery and the common brachio-cephalic trunc (as the most dangerous part of the procedure) in order to reach the ascending aorta, the patient should be asked for a deep inspiration and/or dorsoflexion of his head An Amplatz-II catheter can be used for LCA, RCA and in some cases for LV-angiogram. The sheath should always be removed immediately and hemostasis achieved by radial compression (e.g. clamp). There is a close relationship between access failure respective radial spasm or occlusions and anatomical circumstances (i.e., hypoplastic radial artery, radioulnar loop, or small radial diameters: radial diameter-to-catheter ration < 1.0; assessment by Duplex). Although the radial access can be used in the majority of patients, the use is limited in patients with very small radial diameters and/or with complex lesions (e.g kissing balloon, etc).
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
10:28Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Peripheral Artery Disease III: Interprofessional Care
Cardiac Catheterization III: Left Heart Catheterization
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Cardiac Catheterization II: Right Heart Catheterization
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation