Related Experiment Video
Updated: Jun 4, 2026

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
The effect of the elastic modulus of endodontic posts on static load failure
D A Stewardson1, A C Shortall, P M Marquis
1School of Dentistry, University of Birmingham, Birmingham, UK. d.a.stewardson@bham.ac.uk
Aim:
To compare posts of different flexibility using static load testing. Hypotheses tested were (1) the flexural modulus of endodontic posts does not show a linear relationship with failure load and (2) the flexural modulus of endodontic posts does not show an association with failure mode.
Methodology:
Thirty 2 mm diameter rods of a glass fibre material Aesthetiplus (A), a carbon fibre Composipost (C) and stainless steel (S) were cemented into 90 roots of extracted human teeth using resin cement. Composite resin cores were added and the roots embedded in self-curing acrylic resin. Samples were loaded at 90° in a universal testing machine until failure. Failure loads and fracture levels were compared using one-way anova and post-hoc Scheffé tests. Proportions of different failure modes were compared with Chi square tests (α = 0.05).
Results:
Mean failure loads - MPa (SD) were A - 278.69 (85.79), C - 258.86 (82.05), S - 347.37 (74.50). There was no significant difference in the mean failure load of roots containing the FRC posts (P = 0.639), but it was significantly greater for steel post samples (P < 0.01). The mean level of fracture among the groups was not significantly different (P = 0.879). No root fractures were 'favourable'. Significantly more root fractures and fewer core fractures occurred for group A than for groups C or S (P < 0.01).
Conclusion:
The elastic modulus of an endodontic post does not appear to be a principal factor influencing load at failure or mode of failure of post-restored teeth.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
11:38Environmentally-controlled Microtensile Testing of Mechanically-adaptive Polymer Nanocomposites for ex vivo Characterization
Published on: August 20, 2013
Related Concept Videos
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Residual Stresses in Bending
Elasticity in Concrete
Members Made of Elastoplastic Material
As the bending moment...
Plastic Behavior