Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Pipe Flowrate Measurement01:28

Pipe Flowrate Measurement

In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
Measurement of Fluid Pressure01:16

Measurement of Fluid Pressure

Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Bernoulli's Equation: Problem Solving01:16

Bernoulli's Equation: Problem Solving

A Venturi meter is essential for measuring fluid flow rates in pipelines. It utilizes the relationship between fluid velocity and pressure described by Bernoulli's equation. When installed in a sewage system, the Venturi meter accurately determines the wastewater flow rate by measuring pressure differences.
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...
Pipe Flowrate Measurement: Problem Solving01:28

Pipe Flowrate Measurement: Problem Solving

A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...
Laminar Flow: Problem Solving01:24

Laminar Flow: Problem Solving

Laminar flow occurs when a fluid moves smoothly in parallel layers with minimal mixing and turbulence. In fluid mechanics, ensuring laminar flow within a pipe is essential for precise control of flow characteristics, especially in engineering applications. The key factor in determining whether flow remains laminar is the Reynolds number, a dimensionless quantity that depends on the fluid's velocity, density, viscosity, and the pipe's diameter. A Reynolds number of 2100 or lower indicates...
Pressure Gauges01:20

Pressure Gauges

Most pressure gauges, like those on scuba tanks, are calibrated to read zero at atmospheric pressure. Readings from such gauges are called the gauge pressure, which is the pressure relative to atmospheric pressure. When the pressure inside the tank exceeds atmospheric pressure, the gauge reports a positive value. Some gauges are designed to measure negative pressure. For example, many physics experiments must take place in a vacuum chamber, a rigid chamber from which some of the air is pumped...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

What Outcome Measurement Instruments Are Used to Measure Caregiver Infant-Feeding Practices and the Feeding Environment: A Scoping Review.

Obesity reviews : an official journal of the International Association for the Study of Obesity·2026
Same author

Cosmin reporting guideline for studies on measurement properties of patient-reported outcome measures and its explanation and elaboration document: translation into Brazilian Portuguese.

Quality of life research : an international journal of quality of life aspects of treatment, care and rehabilitation·2026
Same author

Psychometric properties and reference values of nine PROMIS parent-proxy measures for children aged 5 to 7 years in the Netherlands.

Journal of patient-reported outcomes·2026
Same author

Measurement properties of the Inflammatory Rasch-built Overall Disability Scale (I-RODS) in patients with Guillain-Barré syndrome.

Journal of neurology·2026
Same author

Making sense of PROM outcomes: a mixed method study to optimize graphical visualization formats for children.

Quality of life research : an international journal of quality of life aspects of treatment, care and rehabilitation·2026
Same author

Defining Important Aspects of Repigmentation in Vitiligo: Insights From Patients' Perspectives.

Pigment cell & melanoma research·2026

Related Experiment Video

Updated: Jun 4, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
08:25

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship

Published on: January 8, 2019

Smallest detectable change in volume differs between mass flow sensor and pneumotachograph.

Herman Groepenhoff1, Caroline B Terwee, Patrick Mc Jak

  • 1Department of pulmonology and institute for Cardiovascular Research (ICaR-Vu) VU University Medical Center, Amsterdam, 1007 MB, The Netherlands. h.groepenhoff@vumc.nl.

BMC Research Notes
|February 1, 2011
PubMed
Summary

The pneumotachograph offers a smaller detectable change for vital capacity (VC) and alveolar volume (VA) compared to mass flow sensors. This makes the pneumotachograph the preferred device for monitoring lung function changes over time.

More Related Videos

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
05:11

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition

Published on: June 27, 2025

Design and Use of a Full Flow Sampling System (FFS) for the Quantification of Methane Emissions
08:18

Design and Use of a Full Flow Sampling System (FFS) for the Quantification of Methane Emissions

Published on: June 12, 2016

Related Experiment Videos

Last Updated: Jun 4, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
08:25

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship

Published on: January 8, 2019

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
05:11

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition

Published on: June 27, 2025

Design and Use of a Full Flow Sampling System (FFS) for the Quantification of Methane Emissions
08:18

Design and Use of a Full Flow Sampling System (FFS) for the Quantification of Methane Emissions

Published on: June 12, 2016

Area of Science:

  • Pulmonary Function Testing
  • Respiratory Physiology
  • Medical Instrumentation

Background:

  • Mass flow sensors and pneumotachographs are common for assessing pulmonary function changes.
  • A direct comparison of the smallest detectable change (SDC) between these devices is lacking.
  • This study addresses the need to compare the SDC of vital capacity (VC) and single-breath diffusion parameters.

Purpose of the Study:

  • To determine and compare the smallest detectable change (SDC) in vital capacity (VC) and single-breath diffusion parameters.
  • To evaluate the performance of mass flow sensors versus pneumotachographs for detecting subtle lung function variations.
  • To provide evidence for selecting the optimal device for longitudinal pulmonary function monitoring.

Main Methods:

  • Twenty-eight healthy pulmonary function technicians participated in the study.
  • Vital capacity (VC), transfer factor for carbon monoxide (DLCO), and alveolar volume (VA) were measured ten times each.
  • The smallest detectable change was calculated using the formula: 1.96 x Standard Error of Measurement x √2.

Main Results:

  • Pneumotachographs demonstrated a significantly smaller SDC for VC (0.25 L) compared to mass flow sensors (0.53 L) (p=0.04).
  • Similarly, pneumotachographs showed a smaller SDC for VA (0.43 L) than mass flow sensors (0.66 L) (p=0.04).
  • While DLCO showed a trend towards smaller SDC with pneumotachographs (1.18 mmol*kPa⁻¹*min⁻¹) versus mass flow sensors (1.53 mmol*kPa⁻¹*min⁻¹), the difference was not statistically significant (p=0.07).

Conclusions:

  • Pneumotachographs provide a more sensitive measurement for detecting changes in lung volumes (VC and VA) over time.
  • The smaller SDC indicates pneumotachographs are superior for individual patient monitoring of lung function.
  • Mass flow sensors may be less suitable for detecting subtle, clinically significant changes in VC and VA.