Removal of a Günther Tulip filter after 3,006 days
1Departments of Radiology and Surgery and the Penn State Heart and Vascular Institute, Penn State Hershey Medical Center, Penn State University College of Medicine, 500 University Dr, PO Box 850, Mail Code HO66, Hershey, PA 17033, USA. flynch@hmc.psu.edu
Abstract:
Patients may be denied the opportunity to have their inferior vena cava (IVC) filters removed because of a perception that retrievable filters that have been in place for a long period of time may be more technically difficult or hazardous to remove. A case report on the removal of a Günther Tulip filter that was implanted for a total of 3,006 days is presented. This case report adds to the literature that suggests that no time limits may exist after which many retrievable IVC filters can no longer be safely removed.
More Related Videos
05:31Sampling, Sorting, and Characterizing Microplastics in Aquatic Environments with High Suspended Sediment Loads and Large Floating Debris
Published on: July 28, 2018
08:48Analysis of the Ambient Particulate Matter-induced Chromosomal Aberrations Using an In Vitro System
Published on: December 21, 2016
Related Concept Videos
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Filtration
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration