Related Experiment Video
Updated: Jun 4, 2026

20 mJ, 1 ps Yb:YAG Thin-disk Regenerative Amplifier
Published on: July 12, 2017
Interferometric measurement of laser heating in praseodymium-doped YAG crystal
Carlton W Farley1, B Rami Reddy
1Department of Physics, Alabama A&M University, Normal, Alabama 35762, USA.
Abstract:
Temperature measurement is required for many applications but can be difficult in some cases. Laser heating or cooling studies demand accurate measurements of temperature changes. A Michelson interferometer configuration has been used to investigate laser heating in solids. An analytical formula was derived to estimate the temperature change from the fringe count by taking into account the temperature dependence of the sample length and refractive index. When 115 mW of a focused Ar+ laser beam (488 nm) passes through a Pr(3+)-doped YAG sample, its temperature increased by 11.7±1.0 K along the beam path due to nonradiative relaxation. The power dependence of the fringe count/movement was recorded. The temperature change was estimated by the interferometric method and is in agreement with that measured by a thermocouple.