Continuous cardiac output measurement with a Doppler-equipped pulmonary artery catheter

Shigeru Akamatsu1, Yuji Kondo, Norio Ueda

  • 1Department of Anesthesiology & Critical Care Medicine, Matsunami General Hospital, 185-1, Dendai Kasamatsu-cho, Hashima-gun, Gifu 501-6062, Japan. shigeruakamatsu@yahoo.co.jp

Anesthesia and Analgesia
|February 4, 2011
PubMed
Abstract

Related Concept Videos

Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse01:05

Pulse

The pulse is one of the most fundamental physiological indicators of the body's cardiovascular health. It is the rhythmic expansion and contraction of the arterial walls in response to the pressure generated by the heart's pumping action.
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiac Catheterization II: Right Heart Catheterization01:21

Cardiac Catheterization II: Right Heart Catheterization

Right Heart Catheterization: An OverviewRight heart catheterization is an invasive diagnostic procedure that measures right-sided cardiac and pulmonary artery pressures, calculates cardiac output, and identifies intracardiac shunts. It provides detailed hemodynamic data essential for diagnosing and managing various cardiovascular conditions, such as pulmonary hypertension.Access SitesCommon access sites for right heart catheterization include the internal jugular vein in the neck region, the...
Cardiac Output and Stroke Volume01:11

Cardiac Output and Stroke Volume

Cardiac output (CO) is an integral aspect of human physiology, reflecting the heart's efficiency and responsiveness to the body's needs. It represents the volume of blood that the left or right ventricle ejects into the aorta or pulmonary trunk each minute. The CO is calculated by multiplying the heart rate (HR)—the number of heartbeats per minute—by the stroke volume (SV)—the amount of blood pumped out with each heartbeat.
In an average resting adult male, the typical cardiac output averages...
Pulse rhythm01:30

Pulse rhythm

Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: