Determination of Cardiac Output in a Porcine Model for Ex Vivo Pulmonary Perfusion
Published on: June 28, 2024
Continuous cardiac output measurement with a Doppler-equipped pulmonary artery catheter
Shigeru Akamatsu1, Yuji Kondo, Norio Ueda
1Department of Anesthesiology & Critical Care Medicine, Matsunami General Hospital, 185-1, Dendai Kasamatsu-cho, Hashima-gun, Gifu 501-6062, Japan. shigeruakamatsu@yahoo.co.jp
Background:
We developed a Doppler-equipped pulmonary artery catheter that provides continuous measurement of the true main pulmonary blood flow velocity independent of the angle of incidence formed by the pulmonary artery catheter and the main pulmonary artery blood flow. This device uses 2 orthogonally positioned Doppler transducers that allow trigonometric correction for differences in the angle of blood flow between each transducer. We tested the accuracy of the Doppler-equipped pulmonary artery catheter by comparing its cardiac output measurements with those done by conventional techniques in animals.
Methods:
The Doppler-equipped pulmonary artery catheter was evaluated in dogs. A pair of ultrasound Doppler transducers positioned at a fixed angle (90°) was mounted on the distal part of the thermodilution pulmonary artery catheter. The Doppler shifts (Δf1, Δf2) were detected by the 2 transducers sampling at 2 closely spaced points in the main pulmonary artery. The values of Δf1 and Δf2 were used to compute 2 velocity measurements. The true flow velocity of the main pulmonary artery was calculated with the following equation: V(pulm) = {(V(transducer1))(2) + (V(transducer2))(2)}(1/2) (V(pulm) = true main pulmonary artery velocity; V(transducer1) and V(transducer2) = velocity detected by transducers 1 and 2, respectively). The flow velocities were calculated by using a phase differential technique. Cardiac output was calculated as V(pulm) multiplied by a coefficient value. The coefficient value was calculated by dividing cardiac output, derived from conventional techniques, by V(pulm) at the beginning of each experiment. After thoracotomy, an electromagnetic flowprobe was placed around the main pulmonary artery in dogs. Cardiac output was simultaneously measured by the Doppler-equipped pulmonary artery catheter (CO-Doppler), and the electromagnetic flowmeter (CO-EMF) or the thermodilution technique (CO-Thermo). Cardiac output was manipulated by dobutamine and propranolol.
Results:
CO-Doppler was highly correlated with CO-EMF (y = 1.16 × -0.26, r(2) = 0.99, P < 0.001) and CO-Thermo (y = 1.24 × -0.90, r(2) = 0.85, n = 48, P < 0.001). The bias between CO-EMF and CO-Doppler was -0.02 L/min; 95% limits of agreement were -0.32 to 0.28 L/min. The percentage error was 16%. The bias between CO-Thermo and CO-Doppler was 0.18 L/min; 95% limits of agreement were -0.62 to 0.98 L/min.
Conclusions:
The newly developed Doppler-equipped pulmonary artery catheter with 2 orthogonally positioned Doppler transducers allowed accurate and continuous measurements of cardiac output independent of the angle of incidence formed by the pulmonary artery catheter and the main pulmonary artery blood flow.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: