Related Experiment Video
Updated: Jun 4, 2026

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Comparison between the efficiencies of sub-2 μm C18 particles packed in narrow bore columns
Jesse O Omamogho1, Jeremy D Glennon
1Irish Separation Science Cluster (ISSC), Department of Chemistry and the Analytical and Biological Chemistry Research Facility (ABCRF), University College Cork, Cork, Ireland.
Abstract:
The chromatographic performance of two types of core-shell particles and two fully porous particles packed in 2.1 ID × 50 mm columns was investigated. Comparisons of the performances of the EiS-150-C(18) to that of the Kinetex-1.7 μm-C(18), Acquity-BEH-1.7 μm-C(18), and Zorbax-XDB-1.8 μm-C(18) are made and discussed. The physical factors that govern the performance of these columns, such as particle size distribution and column external, total, and particle porosity of the C(18) packing materials were among the prime foci of investigation. The differences in the mass transfer behavior measured using naphtho[2,3-a]pyrene between these columns provides an indication of improved performance of the new EiS-150-C(18) column. The minimum reduced height equivalent to a theoretical plate (HETP) value for the EiS-150-C(18), h(min) = 1.95, was achieved and was comparable to that obtained from the C(18) phases of the Kinetex (h(min) = 2.53), the Acquity (h(min) = 2.26), and the Zorbax (h(min) = 2.57) columns. This study reveals the importance of the dimension of the shell thickness in controlling the performance of columns packed with shell particles in narrow bore columns.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Elution Process
Principles Of Column Chromatography