Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Radiological Investigation II: MRI and Ventilation Perfusion Scan01:30

Radiological Investigation II: MRI and Ventilation Perfusion Scan

Description
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The survival impact of combining radiotherapy and immune checkpoint inhibitors in patients with solid tumors: A systematic review and living meta-analysis of randomized controlled trials.

European journal of cancer (Oxford, England : 1990)·2026
Same author

Automated prospective quality assurance of tumor segmentation and treatment planning in the hypo-FLAME 3.0 trial.

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology·2026
Same author

Diffusion weighted MRI-based hypoxic fraction as a prognostic factor in the FLAME trial prostate cancer cohort.

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology·2026
Same author

Patient-tailored brachytherapy applicator development in compliance with the EU medical device regulation.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
Same author

An algorithmic addition for Carotid Blowout Syndrome type 1.

The Journal of laryngology and otology·2026
Same author

Neoadjuvant ipilimumab plus nivolumab in melanoma: 5-year survival and biomarker analysis from the phase 2 PRADO-trial.

Nature medicine·2026

Related Experiment Video

Updated: Jun 4, 2026

Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
08:54

Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy

Published on: May 8, 2018

IMRT for image-guided single vocal cord irradiation.

Sarah O S Osman1, Eleftheria Astreinidou, Hans C J de Boer

  • 1Department of Radiation Oncology, Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam, The Netherlands. s.osman@erasmusmc.nl

International Journal of Radiation Oncology, Biology, Physics
|February 9, 2011
PubMed
Summary

Intensity-modulated radiotherapy (IMRT) for single vocal cord irradiation effectively covers the target while significantly reducing radiation dose to critical structures, potentially improving patient quality of life.

More Related Videos

Stereotactic Radiosurgery for Gynecologic Cancer
10:35

Stereotactic Radiosurgery for Gynecologic Cancer

Published on: April 17, 2012

Related Experiment Videos

Last Updated: Jun 4, 2026

Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
08:54

Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy

Published on: May 8, 2018

Stereotactic Radiosurgery for Gynecologic Cancer
10:35

Stereotactic Radiosurgery for Gynecologic Cancer

Published on: April 17, 2012

Area of Science:

  • Radiation Oncology
  • Medical Physics
  • Head and Neck Cancer Treatment

Background:

  • Developing image-guided single vocal cord irradiation for T1a glottic carcinoma.
  • Conventional radiotherapy techniques may deliver suboptimal doses to organs at risk.

Purpose of the Study:

  • Compare dose coverage of the affected vocal cord.
  • Evaluate dose delivery to organs at risk.
  • Assess conventional, coplanar IMRT, and non-coplanar IMRT techniques.

Main Methods:

  • Ten patients with T1a glottic carcinoma were analyzed.
  • Treatment plans generated using conventional, coplanar IMRT, and non-coplanar IMRT.
  • Intensity-modulated radiotherapy (IMRT) plans optimized using an in-house algorithm and Monte Carlo dose calculation.

Main Results:

  • All techniques achieved comparable target dose coverage (67 ± 1 Gy).
  • Intensity-modulated radiotherapy (IMRT) significantly reduced contralateral vocal cord dose (39 ± 8 Gy coplanar, 36 ± 6 Gy non-coplanar) compared to conventional plans (66 ± 1 Gy).
  • IMRT demonstrated consistent dose reduction to other critical organs at risk.

Conclusions:

  • Single vocal cord irradiation using intensity-modulated radiotherapy (IMRT) provides excellent target coverage.
  • IMRT significantly spares critical structures, potentially enhancing quality of life post-treatment.
  • This technique holds promise for maintaining local control rates in T1a glottic carcinoma.