Related Experiment Video
Updated: Jun 4, 2026

Identification of Antibacterial Immunity Proteins in Escherichia coli using MALDI-TOF-TOF-MS/MS and Top-Down Proteomic Analysis
Published on: May 23, 2021
Comparison of MALDI-TOF-MS and HPLC-ESI-MS/MS for endopeptidase activity-based quantification of Anthrax lethal
Zsuzsanna Kuklenyik1, Anne E Boyer, Renato Lins
1National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, Georgia 30341, United States.
Abstract:
Diagnosing and treating anthrax at the earliest stage of disease is critical. We developed a method to diagnose anthrax at early stages of infection by detecting anthrax lethal factor (LF) at the attomol/mL level in plasma or serum. This method uses antibody capture and quantification of LF endoproteinase activity by isotope dilution matrix-assisted laser-desorption ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS). Many public health laboratories do not use MALDI-TOF-MS; thus, we have adapted the LF method for detection by electrospray ionization (ESI) tandem MS (MS/MS), which allowed comparison of both MS platforms for LF quantification. Calibration curves were linear from 0.05-2.5 ng/mL when measured after 2 h and from 0.005-1.0 ng/mL after 18 h incubation time. The limit of detection was 0.005 ng/mL using a 200 μL sample. The coefficient of variation for quality control samples was 6-12% for both MS platforms. Samples used to perform cross-validation included 158 serum samples from a study in rabbits exposed to anthrax spores by inhalation. Some were treated with anthrax immune globulin before exposure. Concentrations measured by ESI-MS/MS matched those by MALDI-TOF-MS with p = 0.99 (r(2) = 0.997) and -0.25% mean relative difference (±9% standard deviation). This study shows that isotope dilution MALDI-TOF-MS is a robust and precise quantitative MS platform.
More Related Videos
09:30Analyzing Dynamic Protein Complexes Assembled On and Released From Biolayer Interferometry Biosensor Using Mass Spectrometry and Electron Microscopy
Published on: August 6, 2018
11:09An HS-MRM Assay for the Quantification of Host-cell Proteins in Protein Biopharmaceuticals by Liquid Chromatography Ion Mobility QTOF Mass Spectrometry
Published on: April 17, 2018
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
MALDI-TOF Mass Spectrometry