Related Experiment Video
Updated: Jun 4, 2026

Invasive Hemodynamic Assessment for the Right Ventricular System and Hypoxia-Induced Pulmonary Arterial Hypertension in Mice
Published on: October 24, 2019
The pressure wire as a diagnostic tool in patients with congenital cardiac disease
Tahir Hamid1, Haider Hadi, Bernard Clarke
1Manchester Heart Centre, Manchester Royal Infirmary, University of Central Manchester Foundation NHS Trust, Oxford Road, Manchester, United Kingdom.
Abstract:
The pressure wire has emerged as a useful tool to assess the clinical severity of moderate coronary artery lesions. We report a novel use of the pressure wire in adult patients with complex congenital cardiac disease in whom it was used in assessing pressures beyond the stenosis in the distal pulmonary artery, aorto-pulmonary collaterals, and across prosthetic tricuspid valves, where conventional catheters were unable to reach. We used this in three of our patients for assessment of pulmonary artery pressures and in two patients for assessment of pressures across a prosthetic St Jude® valve. Out of the three patients referred for assessment, only two had significantly raised distal pulmonary pressures enabling them to receive appropriate therapy. Out of the two patients with a prosthetic tricuspid valve, only one required surgery based on this assessment. We describe a novel use of the pressure wire in the functional assessment of adults with congenital cardiac disease in whom conventional catheter techniques may not be able to provide adequate data. It can be a guide to provide appropriate therapy and avoid unnecessary interventions in this patient group.
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pressure Gauges
Cardiac Catheterization III: Left Heart Catheterization
