Related Experiment Video
Updated: Jun 4, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Simultaneous estimation of atorvastatin and its two metabolites from human plasma by ESI-LC-MS/MS
Chinmoy Ghosh1, Ina Jain, Shashank Gaur
1Bio-analytical Department, Cadila Pharmaceuticals Limited, Dholka, Gujarat, India. chinmoy_ghosh@yahoo.com
Abstract:
A selective, sensitive, and fast high performance liquid chromatography (HPLC) method with mass spectrometric (MS) detection mode has been developed and validated completely in human plasma. Atorvastatin (ATO), p-hydroxy atorvastatin (p-HATO), o-hydroxy atorvastatin (o-HATO) and internal standard (IS) are extracted from human plasma via solid phase extraction (SPE) technique. After elution, the solution is evaporated, then reconstituted with 250 µL of Mobile Phase and analyzed using HPLC/MS/MS system. An isocratic mode is used to separate interference peaks using a Symmetry C-18, 75 × 4.6 mm ID, 3.5 µ, column. The m/z of ATO, o-HATO and p-HATO are 559.2/440.2, 575.3/440.4 and 575.0/440.4 respectively. Linearity ranges are 0.05 to 252.92 ng/mL for ATO, p-HATO and o-HATO respectively. Calibration functions, lower limit of quantitation (LLOQ), stability, intra- and inter-day reproducibility, accuracy, and recovery are estimated. This method is free from matrix effects and any abnormal ionization. This method was successfully applied to a single dose 80 mg tablet bioequivalence (BE) study of Atorvastatin. Copyright © 2011 John Wiley & Sons, Ltd.