Internal and external validation strategies for the evaluation of long-term effects in NIR calibration models
Valeria Sileoni1, Frans van den Berg, Ombretta Marconi
1Italian Brewing Research Centre (CERB), University of Perugia , Via San Costanzo, 06126 Perugia, Italy. vale.sileoni@tiscali.it
Abstract:
Some of the practical aspects of long-term calibration-set building are presented in this study. A calibration model able to predict the Kolbach index for brewing malt is defined, and four different validations and resampling schemes were applied to determine its real predictive power. The results obtained demonstrated that one single performance criterion might be not sufficient and can lead to over- or underestimation of the model quality. Comparing a simple leave-one-sample-out cross-validation (CV) with two more challenging CVs with leave-N-samples-out, where the resamplings were repeated 200 times, it is demonstrated that the error of prediction value has an uncertainty, and these values change according to the type and the number of validation samples. Then, two kinds of test-set validations were applied, using data blocks based on the sample collection's year, demonstrating that it is necessary to consider long-term effects on NIR calibrations and to be conservative in the number of factors selected. The conclusion is that one should be modest in reporting the prediction error because it changes according to the type of validation used to estimate it and it is necessary to consider the long-term effects.
Related Concept Videos
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Data Validation
Key parameters for method validation include:
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Reliability and Validity