Errors and Mistakes in Surveying

Errors and mistakes in surveying refer to inaccuracies in measurements and data recording. The errors are deviations from the actual value caused by human sensory limitations, equipment flaws, or environmental effects. These errors are typically unintentional and can result from the inherent imperfections in the instruments used, atmospheric conditions, or the observer’s inability to perceive exact measurements. On the other hand, mistakes are caused by the surveyor's lack of attention,...
Types of Errors: Detection and Minimization01:12

Types of Errors: Detection and Minimization

Error is the deviation of the obtained result from the true, expected value or the estimated central value. Errors are expressed in absolute or relative terms.
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Errors in Taping01:18

Errors in Taping

Errors in taping arise from multiple factors that can significantly impact measurement accuracy in surveying. Misalignment of the tape, often due to human error, is one primary source. A skilled rear tapeman, using a telescope, can help correct alignment by guiding the head tapeman; however, human limitations still lead to small inaccuracies. These errors may include misplacement of pins or inaccurate tape readings due to common visual confusions, such as mistaking a six for a nine. Such...
Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
Detection of Gross Error: The Q Test01:00

Detection of Gross Error: The Q Test

When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
Systematic Error: Methodological and Sampling Errors01:15

Systematic Error: Methodological and Sampling Errors

In the case of systematic errors, the sources can be identified, and the errors can be subsequently minimized by addressing these sources. According to the source, systematic errors can be divided into sampling, instrumental, methodological, and personal errors.
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same journal

Motor and sensory outcomes after botulinum toxin A injection versus unilateral medial rectus recession in small-to-moderate angle esotropia.

Strabismus·2026
Same journal

Bimedial rectus recession versus botulinum toxin injection for the treatment of infantile esotropia.

Strabismus·2026
Same journal

Worsening abducens paresis and chronic orbital venous congestion after carotid-cavernous fistula embolization: long-term motility outcomes.

Strabismus·2026
Same journal

Strabismus following Endonasal sinus surgery: a 10-year retrospective analysis of clinical profile and outcomes.

Strabismus·2026
Same journal

Correction.

Strabismus·2026
Same journal

Surgical management of iatrogenic medial rectus transection following functional endoscopic sinus surgery: a report of two cases.

Strabismus·2026
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jun 4, 2026

Proofreading and DNA Repair Assay Using Single Nucleotide Extension and MALDI-TOF Mass Spectrometry Analysis
11:08

Proofreading and DNA Repair Assay Using Single Nucleotide Extension and MALDI-TOF Mass Spectrometry Analysis

Published on: June 19, 2018

Errata

    Strabismus
    |February 15, 2011
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Correction of Presbyopia by Monocular Bi-Aspheric Ablation Profile
    05:46

    Correction of Presbyopia by Monocular Bi-Aspheric Ablation Profile

    Published on: September 20, 2024

    Related Experiment Videos

    Last Updated: Jun 4, 2026

    Proofreading and DNA Repair Assay Using Single Nucleotide Extension and MALDI-TOF Mass Spectrometry Analysis
    11:08

    Proofreading and DNA Repair Assay Using Single Nucleotide Extension and MALDI-TOF Mass Spectrometry Analysis

    Published on: June 19, 2018

    Correction of Presbyopia by Monocular Bi-Aspheric Ablation Profile
    05:46

    Correction of Presbyopia by Monocular Bi-Aspheric Ablation Profile

    Published on: September 20, 2024