Related Experiment Video
Updated: Jun 4, 2026

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Dual optical sensor for oxygen and temperature based on the combination of time domain and frequency domain
Hung Lam1, Govind Rao, Joana Loureiro
1Center of Advanced Sensor Technology, Department of Chemical and Biochemical Engineering, University of Maryland Baltimore County, 1000 Hilltop Circle, Baltimore, MD 21250, USA.
Abstract:
In measuring specific conditions in the real world, there are many situations where both the oxygen concentration and the temperature have to be determined simultaneously. Here we describe a dual optical sensor for oxygen and temperature that can be adapted for different applications. The measurement principle of this sensor is based on the luminescence decay times of the oxygen-sensitive ruthenium complex tris-4,7-diphenyl-1,10-phenanthroline ruthenium(III) [Rudpp] and the temperature-sensitive europium complex tris(dibenzoylmethane) mono(5-amino-1,10-phenanthroline)europium(III) [Eudatp]. The excitation and emission spectra of the two luminophores overlap significantly and cannot be discriminated in the conventional way using band pass filters or other optical components. However, by applying both the frequency and time domain techniques, we can separate the signals from the individual decay time of the complexes. The europium complex is entrapped in a poly(methyl methacrylate) (PMMA) layer and the ruthenium complex is physically adsorbed on silica gel and incorporated in a silicone layer. The two layers are attached to each other by a double sided silicone based tape. The europium sensing film was found to be temperature-sensitive between 10 and 70°C and the ruthenium oxygen-sensitive layer can reliably measure between 0 and 21% oxygen.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...

