A monoclonal antibody-based immunosensor for detection of Sudan I using electrochemical impedance spectroscopy
Fei Xiao1, Ningdan Zhang, Hongjie Gu
1Department of Chemistry, East China Normal University, Shanghai 200062, PR China.
Sudan I monoclonal antibodies (Mabs) were prepared by hybridoma technique and firstly used to develop a Sudan I immunosensor by immobilizing the Mabs on a gold electrode. o-Mercaptobenzoic acid (MBA) was covalently conjugated on the gold electrode to form a self-assembled monolayer (SAM). The immobilization of Sudan I Mabs to the SAM was carried out through a stable acyl amino ester intermediate generated by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydrosuccinimide (NHS), which could condense antibodies reproducibly and densely on the SAM. The changes of the electrode behavior after each assembly step were investigated by cyclic voltammetric (CV) technique. The Sudan I concentration was measured through the increase of impedance values in the corresponding specific binding of Sudan I and Sudan I antibody. A linear relationship between the increased electron-transfer resistance (Ret) and the logarithmic value of Sudan I concentrations was found in the range of 0.05-50 ng mL(-1) with the detection limit of 0.03 ng mL(-1). Using hot chili as a model sample, acceptable recovery of 96.5-107.3% was obtained. The results were validated by conventional HPLC method with good correlation. The proposed method was proven to be a feasible quantitative method for Sudan I analysis with the properties of stability, highly sensitivity and selectivity.
Sudan I monoclonal antibodies (Mabs) were prepared by hybridoma technique and firstly used to develop a Sudan I immunosensor by immobilizing the Mabs on a gold electrode. o-Mercaptobenzoic acid (MBA) was covalently conjugated on the gold electrode to form a self-assembled monolayer (SAM). The immobilization of Sudan I Mabs to the SAM was carried out through a stable acyl amino ester intermediate generated by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydrosuccinimide (NHS), which could condense antibodies reproducibly and densely on the SAM. The changes of the electrode behavior after each assembly step were investigated by cyclic voltammetric (CV) technique. The Sudan I concentration was measured through the increase of impedance values in the corresponding specific binding of Sudan I and Sudan I antibody. A linear relationship between the increased electron-transfer resistance (Ret) and the logarithmic value of Sudan I concentrations was found in the range of 0.05-50 ng mL(-1) with the detection limit of 0.03 ng mL(-1). Using hot chili as a model sample, acceptable recovery of 96.5-107.3% was obtained. The results were validated by conventional HPLC method with good correlation. The proposed method was proven to be a feasible quantitative method for Sudan I analysis with the properties of stability, highly sensitivity and selectivity.
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Microbial Biosensors