Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Unknown exposures: gaps in basic characterization addressed with person-portable gas chromatography-mass spectrometry
Philip A Smith1, Marc T A Roe, Charles Sadowski
1Department of Preventive Medicine and Biometrics, Uniformed Services University of the Health Sciences, Bethesda, Maryland, USA. Smith.Philip.A@dol.gov
Abstract:
A newly developed person-portable gas chromatography-mass spectrometry (GC-MS) system was used to analyze several solvent standards, contact cement, paint thinner, and polychlorinated biphenyl samples. Passive solid phase microextraction sampling and fast chromatography with a resistively heated low thermal mass GC column were used. Results (combined sampling and analysis) were obtained in <2 min for solvent, contact cement, and paint thinner samples, and in <13 min for the polychlorinated biphenyl sample. Mass spectra produced by the small toroidal ion trap detector used were similar to those produced with heavily used transmission quadrupole mass spectrometers for polychlorinated biphenyl compounds, simple alkanes, and cycloalknes, while mass spectra for benzene and the ketone compounds analyzed showed evidence for ion/molecule reactions in the ion trap. For one of the contact cement samples analyzed, no evidence was found to indicate the presence of n-hexane, although the relevant material safety data sheet listed this ingredient. Specific chemical constituents corresponding to a potentially wide range of petroleum distillate compounds were identifiable from GC-MS analyses. The possibility for an improved basic characterization step in the exposure assessment process exists with the availability of fast, person-portable GC-MS, although work is needed to further refine this tool and understand the best ways it may be used.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...