Related Experiment Videos
[Personal monitoring method for volatile chloroorganic compounds]
T Matsumura1, K Kametani, M Takeda
1National Institute of Hygienic Sciences.
Abstract:
A method for measurement of volatile chloroorganic compounds (VCOCs) in air by using porous polymer resin beads, Porapak N was developed as follows: 1. Air was sampled in a glass collection tube packed with Porapak N (1.2 g) at flow rate of 30 ml/min for 24 hours at room temperature. 2. The collection tube was set in a desorption device. The VCOCs adsorbed on the Porapak N were desorbed by heating in a nitrogen flow (180 degrees C, 50 ml/min) and trapped in 10 ml n-hexane cooled by ice. Sufficient recoveries were obtained at desorption time of 8 min. 3. The VCOCs were determined by a gas chromatograph with an electron capture detector (GC-ECD). The present method was applied to determine personal exposure levels for VCOCs. Personal exposure levels of 1,1,1-trichloroethane, carbon tetrachloride, trichloroethylene and tetrachloroethylene were 1.1-6.9, 0.1-0.9, N.D-0.4 and N.D.-4.2 ppb, respectively.