A simple, innovative way to reduce rhinitis symptoms after sedation during endoscopy
Nai-Liang Li1, Shiang-Chung Tseng, Che-Chang Hsu
1Department of Anesthesiology, Koo Foundation, Sun Yat-Sen Cancer Center, Taipei, Taiwan.
Background:
Supplmental oxygen is routinely given via nasal cannula (NC) to patients undergoing moderate sedation for endoscopy. Some patients complain of profuse rhinorrhea and⁄or sneezing after the procedure, which results in additional medical costs and patient dissatisfaction.
Objectives:
To determine the causal relationship between the route of oxygen delivery and troublesome nasal symptoms, and to seek possible solutions.
Methods:
Patients (n=836) were randomly assigned to one of the three following groups: the NC group (n=294), the trimmed NC (TNC) group (n=268) and the nasal mask (NM) group (n=274). All received alfentanil 12.5 μg⁄kg and midazolam 0.06 mg⁄kg, and adjunct propofol for sedation. Supplemental oxygen at a flow rate of 4 L⁄min was used in the NC and TNC groups, and 6 L⁄min in the NM group. The incidence of nasal symptoms and hypoxia were assessed.
Results:
The incidence of rhinitis symptoms was significantly higher in the NC group (7.1%) than in the TNC (0.4%) and NM (0%) groups (P<0.001). The incidence of hypoxia was lower in the NC group (3.1%) (P=0.040). All hypoxia events were transient (ie, less than 30 s in duration). On spirometry, the mean value of the lowest saturation of peripheral oxygen was found to be significantly lower in the NM group (96.8%) than in the NC group (97.7%) (P=0.004).
Conclusions:
Trimming the NC or using NMs reduced the incidence of rhinitis symptoms; however, the incidence of hypoxia was higher. Further investigation regarding the efficiency of oxygen supplementation is warranted in the design of novel oxygen delivery devices.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Inhalational Anesthetics: Overview
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...