Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jun 4, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
08:34

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies

Published on: February 6, 2019

A RapidArc planning strategy for prostate with simultaneous integrated boost.

David Jolly1, Dineli Alahakone, Juergen Meyer

  • 1Wellington Blood & Cancer Centre, Capital and Coast District Health Board, Wellington, New Zealand. david.jolly@ccdhb.org.nz

Journal of Applied Clinical Medical Physics
|February 19, 2011
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Commissioning and Quality Assurance of Catalyst<sup>+</sup> HD Surface-guided Radiotherapy on TrueBeam HyperArc Linear Accelerator: An Indian Experience in Precision Radiotherapy.

Journal of medical physics·2026
Same author

A National Survey of Medical Physicists: Part 2-Assessing Work Effort and Perceived Challenges and Satisfaction in HDR Brachytherapy.

International journal of radiation oncology, biology, physics·2026
Same author

A National Survey of Medical Physicists: Part 1-Practice Patterns for High-Dose-Rate Brachytherapy.

International journal of radiation oncology, biology, physics·2026
Same author

A hybrid IGRT workflow using SGRT and CBCT for prostate SBRT: Feasibility, efficiency, and safety.

Journal of applied clinical medical physics·2025
Same author

Design and dosimetric characterization of a transportable proton minibeam collimation system.

Frontiers in oncology·2025
Same author

Commissioning a clinical proton pencil beam scanning beamline for pre-clinical ultra-high dose rate irradiations on a cyclotron-based system.

Frontiers in oncology·2024

A new planning strategy for RapidArc radiotherapy, a rotational form of intensity-modulated radiation therapy, offers comparable or improved dose distributions. This streamlined approach reduces treatment planning time and planner dependency.

Area of Science:

  • Radiation Oncology
  • Medical Physics

Background:

  • Rotational radiotherapy techniques, such as RapidArc, offer potential advantages over static gantry intensity-modulated radiotherapy (IMRT).
  • Existing studies suggest improved dose distributions, reduced monitor units, and shorter treatment times with rotational IMRT.
  • A standardized and rigorous planning approach for these advanced techniques is still needed.

Purpose of the Study:

  • To outline a robust and streamlined planning strategy for RapidArc radiotherapy, specifically for prostate cancer with a simultaneous integrated boost.
  • To provide a detailed methodology including field setup, optimization objectives, and user interactions.
  • To validate the proposed strategy through a comparative planning study against static gantry IMRT.

Main Methods:

  • Development of a specific planning strategy for RapidArc, focusing on prostate SIB cases.

More Related Videos

Radiation Planning Assistant - A Web-based Tool to Support High-quality Radiotherapy in Clinics with Limited Resources
05:18

Radiation Planning Assistant - A Web-based Tool to Support High-quality Radiotherapy in Clinics with Limited Resources

Published on: October 6, 2023

A New Technique for Treating Low-risk Prostate Cancer&#8212;Super Active Surveillance
05:19

A New Technique for Treating Low-risk Prostate Cancer—Super Active Surveillance

Published on: November 7, 2025

Related Experiment Videos

Last Updated: Jun 4, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
08:34

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies

Published on: February 6, 2019

Radiation Planning Assistant - A Web-based Tool to Support High-quality Radiotherapy in Clinics with Limited Resources
05:18

Radiation Planning Assistant - A Web-based Tool to Support High-quality Radiotherapy in Clinics with Limited Resources

Published on: October 6, 2023

A New Technique for Treating Low-risk Prostate Cancer&#8212;Super Active Surveillance
05:19

A New Technique for Treating Low-risk Prostate Cancer—Super Active Surveillance

Published on: November 7, 2025

  • Detailed description of field setup, initial objectives, and optimization/post-optimization adjustments.
  • Comparative planning study evaluating RapidArc against static gantry IMRT, assessing plan quality and planning time.
  • Main Results:

    • The developed RapidArc planning strategy resulted in optimization times of 15 ± 1.3 minutes.
    • Comparative analysis showed results consistent with previous studies, supporting the efficacy of rotational techniques.
    • The strategy demonstrated a reduction in dependence on planner experience, streamlining the process.

    Conclusions:

    • The proposed planning strategy for RapidArc in prostate SIB cases is robust and efficient.
    • This approach has the potential to significantly streamline radiotherapy planning workflows in clinical departments.
    • Implementing this strategy can lead to consistent, high-quality treatment plans regardless of planner expertise.