Segmentation and Measurement of Fat Volumes in Murine Obesity Models Using X-ray Computed Tomography
Published on: April 4, 2012
X-ray phase-contrast tomography of porcine fat and rind
Torben H Jensen1, Arvid Böttiger, Martin Bech
1Niels Bohr Institute, University of Copenhagen, Copenhagen, Denmark. torbenhaugaardjensen@gmail.com
Abstract:
X-ray computed tomography (CT) has recently received increased attention in the food science community. The aim of this paper is to demonstrate how grating based phase-contrast CT can provide contrast superior to standard absorption based CT. The method of phase-contrast CT is applied to two samples of porcine subcutaneous fat and rind. The additional contrast obtained may be used for quality testing, to investigate variations in fatty acid composition of the fat-fraction, and density variations in the meat-fraction. The possibility of integrating the method into an abattoir environment is discussed.
Related Concept Videos
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...