Mass Spectrometric Analysis of Glycosphingolipid Antigens
Published on: April 16, 2013
Mass spectrometric stereoisomeric differentiation between α- and β-ascorbic acid 2-O-glucosides. Experimental and
Basem Kanawati1, Veronica von Saint Paul, Constanze Herrmann
1Institute of Ecological Chemistry, Helmholtz Zentrum München, German Research Center for Environmental Health, Neuherberg, Germany. Basem.Kanawati@helmholtz-muenchen.de
Abstract:
L-Ascorbic acid and two distinct anomers, namely the α-D-glucopyranosyl and β-D-glucopyranosyl-(1→2)-L-ascorbic acid (stereoisomers), were studied within the scope of collision-induced dissociation (CID) experiments, performed by linear ion acceleration and collision with argon atoms inside a hexapole quadrupole hexapole ion beam guide, which is coupled to an ion cyclotron resonance (ICR) cell with a 12 Tesla magnet for high-resolution measurements. Loss of C(2)H(4)O(2) neutral from the [M-H](-) anion of L-ascorbic acid was observed. Density functional theory (DFT) calculations on the 6-311+G(2d,p)//6-31+G(d) level of theory reveal a new concerted mechanism for an intramolecular gas-phase rearrangement, through which the observed ejected neutral C(2)H(4)O(2) can take place. A similar rearrangement also occurs in the case of α- and β-D-glucopyranosyl-(1→2)-L-ascorbic acid. For the α isomer, only homolytic glycoside fragmentation was observed. For the β isomer, both homolytic and heterolytic glycoside cleavages were possible. The mechanisms behind all observed fragmentation pathways were fully understood by the implementation of accurate DFT calculations. Stereoisomeric differentiation between α and β isomers of the L-ascorbic acid-2-O-glucoside could be revealed by tandem mass spectrometry (MS/MS) experiments and were explained theoretically.
Related Concept Videos
Spectroscopy of Carboxylic Acid Derivatives
In the...
NMR and Mass Spectroscopy of Carboxylic Acids
While α protons of carboxylic acids absorb at 2–2.5 ppm, β protons absorb further upfield.
Carboxylic acids are easily identified by dissolving them in deuterium oxide, which results in a rapid exchange of the acidic protons with deuterium. This leads to the disappearance of the acidic...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...