Related Experiment Video
Updated: Jun 4, 2026

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
Justification of diagnostic medical exposures: some practical issues. Report of an International Atomic Energy Agency
J Malone1, R Guleria, C Craven
1Radiation Protection of Patients Unit, Radiation Safety and Monitoring Section, NSRW, International Atomic Energy Agency, Vienna, Austria. jfmalone@tcd.ie
Objectives:
The Radiation Protection of Patients Unit of the International Atomic Energy Agency (IAEA) is concerned about the effectiveness of justification of diagnostic medical exposures. Recent published work and the report of an initial IAEA consultation in the area gave grounds for such concerns. There is a significant level of inappropriate usage, and, in some cases, a poor level of awareness of dose and risk among some key groups involved. This article aims to address this.
Methods:
The IAEA convened a second group of experts in November 2008 to review practical and achievable actions that might lead to more effective justification.
Results:
This report summarises the matters that this group considered and the outcome of their deliberations. There is a need for improved communication, both within professions and between professionals on one hand, and between professionals and the patients/public on the other. Coupled with this, the issue of consent to imaging procedures was revisited. The need for good evidence-based referral guidelines or criteria of acceptability was emphasised, as was the need for their global adaptation and dissemination.
Conclusion:
Clinical audit was regarded as a key tool in ensuring that justification becomes an effective, transparent and accountable part of normal radiological practice. In summary, justification would be facilitated by the "3 As": awareness, appropriateness and audit.
More Related Videos
Related Concept Videos
Biological Effects of Radiation
Mutagenicity and Carcinogenicity
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force per...
Atomic Emission Spectroscopy: Interference
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...

