Temperature modulation and quadrature detection for selective titration of two-state exchanging reactants

K Zrelli1, T Barilero, E Cavatore

  • 1Département de Chimie, Ecole Normale Supérieure, UMR CNRS-ENS-UPMC Paris 06 8640 Pasteur, 24 rue Lhomond, 75231 Paris Cedex 05, France.

Analytical Chemistry
|March 2, 2011
PubMed
Summary

This study introduces a novel dynamic detection method for molecular quantification in complex biological samples. The technique achieves high selectivity by analyzing interaction dynamics, enabling accurate measurements even with interfering substances present.

Related Concept Videos

Potentiometric Titration: Overview01:31

Potentiometric Titration: Overview

Potentiometric titration is a quantitative analytical technique that determines the concentration of an analyte by measuring the potential difference between the two electrodes in the solution. The endpoint of a potentiometric titration is the point at which there is a significant change in the potential difference. It occurs when the stoichiometric reaction between the analyte and the titrant is complete. The endpoint is usually determined graphically by plotting the measured potential...
Controlled-Current Coulometry: Coulometric Titration01:18

Controlled-Current Coulometry: Coulometric Titration

Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Classification of Titrimetric Analysis Based on Reaction Types01:01

Classification of Titrimetric Analysis Based on Reaction Types

Titrimetric analysis in solution chemistry involves measuring the volume of solutions and is often called volumetric analysis. The standard solution of known concentration in the burette is called the titrant, whereas the solution of unknown concentration in the flask is called the analyte, or titrand. Titrimetric analyses can be classified into four types based on the reactions between the titrant and analyte.
Titrations between an acid and a base lead to neutralization reactions that form...
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
Titrimetric Methods: Types and Commonly Used Strategies01:08

Titrimetric Methods: Types and Commonly Used Strategies

In chemistry, titrimetric methods are broadly classified into three types: volumetric, gravimetric, and coulometric. Volumetric titrations involve measuring the volume of a titrant of known concentration that is required to react completely with an analyte. In gravimetric titrations, the standard solution reacts with the analyte to form an insoluble precipitate, which is filtered, dried, and weighed. In coulometric titrations, current is applied to an electrochemical reaction until the reaction...
EDTA: Indirect and Alkalimetric Titration01:23

EDTA: Indirect and Alkalimetric Titration

Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...