Body plethysmography--its principles and clinical use.
C P Criée1, S Sorichter, H J Smith
1Evangelisches Krankenhaus Göttingen-Weende gGmbH, Department of Pneumology, Respiratory Care, Sleep Medicine, Pappelweg 5, D-37120 Bovenden-Lenglern, Germany. criee@ekweende.de
Body plethysmography measures lung volumes like functional residual capacity (FRC) and airway resistance (Raw). This technique provides detailed insights into respiratory function beyond standard spirometry.
Area of Science:
- Pulmonary Function Testing
- Respiratory Physiology
Background:
- Body plethysmography is a key method for assessing lung volumes and airway resistance.
- Standard spirometry offers limited insights compared to plethysmography's detailed measurements.
Purpose of the Study:
- To explain the working principles of body plethysmography.
- To highlight the additional diagnostic information provided by body plethysmography compared to spirometry.
Main Methods:
- Utilizes a sealed body box to measure pressure variations.
- Calculates functional residual capacity (FRC) and specific airway resistance (sRaw).
- Determines airway resistance (Raw) from sRaw and FRC(pleth).
Main Results:
- FRC(pleth) and sRaw are primary measures obtained.
- Airway resistance (Raw) is derived, indicating airway obstruction.
- The method measures 'shift volume' via box pressure variations.
Conclusions:
- Body plethysmography provides a comprehensive understanding of respiratory mechanics.
- It offers significant advantages over spirometry in assessing lung function.
- The technique has potential for further advancements in respiratory diagnostics.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...