Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Multi-stage preconcentrator/focuser module designed to enable trace level determinations of trichloroethylene in
Thitiporn Sukaew1, Hungwei Chang, Gustavo Serrano
1Department of Environmental Health Sciences, University of Michigan, Ann Arbor, Michigan 48109-2029, USA.
Abstract:
This article describes the development and characterization of a multi-stage preconcentrator/focuser (PCF) module designed to be integrated with a microfabricated gas chromatograph (µGC) for autonomous, in situ determinations of volatile organic compounds. The PCF module has been optimized specifically for the determination of trichloroethylene (TCE) vapors at low- or sub-parts-per-billion concentrations in the presence of common indoor air co-contaminants in residences at risk of vapor intrusion (VI) from surrounding TCE-contaminated soil. It consists of three adsorbent-packed devices arranged in series: a pre-trap of conventional (tubular metal) design for capturing interferences with vapor pressures <3 torr; a high-volume sampler, also of conventional design, for capturing (and transferring) TCE and other compounds with vapor pressures within the range of ~3 to 95 torr; and a microfocuser (µF) consisting of a micromachined Si chamber with an integrated microheater for focusing and injecting samples into the separation module. The adsorbent masses, sampling and desorption flow rates, and heating profiles required for selective, quantitative capture and transfer/injection of TCE are determined for each of the devices, and the assembled PCF module is used to analyze a test atmosphere containing 200 parts-per-trillion of TCE and 27 relevant co-contaminants with a conventional downstream capillary column and electron-capture detector. An average TCE transfer efficiency of 107% is achieved for a 20 L air sample, with a preconcentration factor of ~800,000.
More Related Videos
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.