Related Experiment Video
Updated: Jun 4, 2026

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Semi-automated liquid chromatography-mass spectrometry (LC-MS/MS) method for basic pesticides in wastewater effluents
Michael G Cahill1, Giovanni Caprioli, Mary Stack
1Environmental Research Institute, University College Cork, Lee Road, Cork, Ireland.
Abstract:
Effluent from wastewater treatment plants have been identified as an important source of micro-organic contaminants in the environment. An online high-performance liquid chromatography-heated electrospray ionization tandem mass spectrometric method was developed and validated for the determination of basic pesticides in effluent wastewaters. Most available methods for pesticide analysis of wastewater samples are time-consuming, require complex clean-up steps and are difficult to automate. The method developed used a simple solid-phase extraction clean-up for salt and lipid reduction. On-line sample pre-concentration was performed using a reversed phase (C(18)) column, and analytes were separated by back-flushing onto an analytical column (C(8)) with detection using QqQ MS. An option to increase MS resolution was exploited to minimize interference from endogenous compounds in the matrix. A better than unit mass resolution was used (Q1 full width half maximum (FWHM) = 0.2 Da and Q3 FWHM = 0.7 Da), which was as rugged as a unit resolution method, and improved signal/noise and better detection limits were achieved for the targeted basic pesticides. This method was applied to the determination of 11 pesticides, including methoxytriazine, chlorotriazines, chloroacetanilides, phenylurea and carbamate pesticides. The percentage recovery values for these pesticides using the online trapping column were within the range, 73-95%, with relative standard deviation (RSD) values <8.9%. The highest concentrations of these pesticides in wastewater effluents in County Cork, Ireland, were simazine (0.51 μg/L), prometon (0.14 μg/L), diuron (0.21 μg/L) and atrazine (0.19 μg/L).
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
07:10Untargeted Liquid Chromatography-Mass Spectrometry-Based Metabolomics Analysis of Wheat Grain
Published on: March 13, 2020
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...