The application of two total transfer valve modulators for comprehensive two-dimensional gas chromatography of
Richard T Lidster1, Jacqueline F Hamilton, Alastair C Lewis
1Department of Chemistry, University of York, Heslington, York, UK. rtl500@york.ac.uk
Abstract:
Rotary and diaphragm 6-port 2-position valves have been evaluated as modulators for comprehensive GC. A total transfer methodology was used such that all analyte materials from the primary column were passed to the second separating column. The transfer methodology used repeated short periods of stop flow, but retained good primary column performance since primary carrier flow was partially maintained as pressure equilibrated along the length of the first column. Highly resolved separations of complex samples such as petrol and essential oils were achieved with equivalent performance (in terms of second column resolution) to thermal modulation with flame ionisation detection (FID). The valve modulators tested could outperform thermal modulators for very highly volatile organic species since the modulation process was insensitive to analyte vapour pressure. The diaphragm valve tested showed the best performance and was incorporated with a thermal desorption system to provide a high sensitivity separation of volatile organic compounds (VOCs) in air with LODs for individual VOCs of 2-4 pptV for a 1-L air sample.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...