Measurement of the resistivity of porous materials with an alternating air-flow method

Raffaele Dragonetti1, Carmine Ianniello, Rosario A Romano

  • 1Dipartimento di Energetica, Termofluidoidinamica applicata e Condizionamenti Ambientali, Università di Napoli Federico II, piazzale Tecchio 80, 80125 Napoli, Italy.

Related Concept Videos

Resistivity01:22

Resistivity

When a voltage is applied to a conductor, an electrical field is generated, and charges in the conductor feel the force due to the electrical field. The current density that results depends on the electrical field and the properties of the material. In some materials, including metals at a given temperature, the current density is approximately proportional to the electrical field. In these cases, the current density can be modeled as:
Measurement of Air Content in Concrete01:23

Measurement of Air Content in Concrete

Air content measurement in concrete is critical for ensuring structural integrity and durability of concrete structures, especially in environments prone to severe weather conditions. Accurate air content analysis optimizes concrete's resistance to freeze-thaw cycles and enhances its workability and strength. Several methods are standardized under ASTM guidelines to measure the air content in fresh concrete, each suitable for different concrete types and conditions.
The pressure method,...
Resistance01:19

Resistance

When a current moves through any conductor, the conductor causes some level of difficulty for the current to flow. The measure of that difficulty is known as the resistance of the material and is represented by R. Every material has its own resistance. In the case of conductors, heat is emitted whenever a current passes through them. Resistance depends on the resistivity of the material. Resistivity is a characteristic of the material used to fabricate electrical components, whereas the...
Porosity and Absorption of Aggregate01:20

Porosity and Absorption of Aggregate

Aggregates contain pores of varying sizes; while some are completely enclosed within the particles, others open onto the surface, allowing water to penetrate. The porosity of aggregates is a major factor contributing to the overall porosity of concrete, given that aggregates constitute about three-quarters of concrete's volume.
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the aggregate...
Resistance and Conductance01:25

Resistance and Conductance

A conductor's DC resistance at a given temperature is influenced by its resistivity, length, and cross-sectional area. Resistivity is an inherent property of the conductor material, with annealed copper serving as the international standard for measurement. For instance, the resistivity of hard-drawn aluminum at 20 degrees Celsius is 61% of the standard conductivity of annealed copper.
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their length...
Ohm's Law01:19

Ohm's Law

Resistors are fundamental components in electrical circuits, often manufactured from metallic alloys or carbon compounds. They model a material's ability to resist the flow of electric current, a characteristic that is crucial in controlling and regulating electrical power within a circuit.
This current-resisting behavior of resistors is governed by Ohm's law, which states that the voltage across a resistor is directly proportional to the current flowing through it.