Aim:
There is uncertainty about the best method of withdrawing supplemental oxygen in babies with chronic neonatal lung disease (CNLD). Some authors advocate withdrawal of oxygen in the day, but continuing supplementation during sleep, based on early work suggesting that oxygen saturations are lower during sleep, which did not accord with our clinical impression. We re-examined the hypothesis that babies have lower saturations while asleep.
Methods:
We studied infants with CNLD during the day, while awake and asleep. We recorded video with simultaneous real-time capture of oxygen saturation (SpO2), heart rate and plethysmographic waveform from pulse oximetry. Behavioural state was scored using observation and video and classified as awake (feeding, active or quiet) or sleep.
Results:
Thirteen infants had analysable data, although one had strikingly lower SpO2 values while awake and was excluded from analysis. The infants had a median gestation of 26 weeks and were studied at a median (range) postmenstrual age of 66 (37-130) weeks, for 229 (89-330) min. Mean SpO2 was 97.6% during sleep and 97.0% awake (p=0.011).
Conclusion:
Babies with CNLD have lower oxygen saturation while awake. There is no physiological justification for increasing oxygen during sleep, or withdrawing selectively during the daytime, although larger studies are needed to confirm this finding.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Volumes and Capacities I